Select up to 3 products
Filters large particles from Tap water and reduces hardness prior to reverse osmosis purification
Insta-TEST® Chlorine Dioxide is a convenient way to test for Chlorine Dioxide levels in sanitized water. Range and sensitivity is 0, 10, 25, 50, 100, 250, 500 ppm. Range and sensitivity is 0, 0.25, 0.5, 1, 3, 10 ppm.
Tests for the EPA limit of 15 ppb (μg/L) Lead in water The Lead Water Test for water quality testing is a revolutionary product designed to make testing for Lead safe, easy, and affordable. This patent pending device utilizes a lateral flow test strip, similar in technology to home pregnancy and...
Low Cost, Easy to use kits for testing a wide range of water quality Parameters Continuous gradient color disks provide accurate measurements—no need to “extrapolate” between discrete color blocks Rotate the color wheel to obtain a color match with the reacted sample and read your result in the...
R2A Agar is recommended for enumeration of heterotrophic bacteria in water, especially potable water. This product is not intended to be used for the diagnosis of human disease.
Contents: 30 mL Hydrogen Peroxide 3% 30 mL Chloride Reagent A 30 mL Sulfuric Acid, 0.5N 15 mL Phenolphthaein Indicator 0.5% 2 x 30 mL Silver Nitrate 0.171 N 1 Sample Tube, 5-10-25 mL w/ cap
UN Number: UN3316
QUANTOFIX Nitrite 3000 semi-quantitative test strips for the determination of high concentrations of nitrite (NO 2) in solutions. Measuring range: 0-0.1-0.3-0.6-1-2-3 g/L NO2-
Spectroquant® Nitrite Test Method: photometric
Tube test for the determination of ortho- and total Phosphate. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Phosphate (ortho) - 0.30–15.00 mg/L P , Phosphate (ortho) - 1–45.0...
Standard test for the determination of Phenols. Reagent kit for highly sensitive photometric measurements with low costs per sample. Pre-programmed on NANOCOLOR photometers. Measuring range: Phenols - 0.01–7.0 mg/L Phenol
The ColorQ Pool 4 measures four basic pool and spa tests, Free Chlorine (0 to 10 ppm); Total Chlorine (0 to 10 ppm); Bromine (0 to 22 ppm) and pH (6.5 to 8.5 pH). As a bonus, the ColorQ Pool 4 can also measure Total Alkalinity (Code 7038-G), Calcium Hardness (Code 7041-G and 7042-G), and Cyanuric...
The LaMotte 0 - 15 ppm ColorQ nitrate TesTabs are suitable for use with ColorQ and ColorQ 2x test kits. They are mainly used in research facilities and chemical laboratories to conduct wide range of experiments. They are easy and convenient to use.
UN Number: UN1830
Tube test for the determination of COD. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: COD - 1.0–15.0 g/L O2, COD - 1000–15000 mg/L O2
Test tap water from any source and study the impact of urban water on the city’s environment. "Wet in the City," a hands-on kit, introduces the basic concepts of water chemistry–even to kids as young as third grade! Non-hazardous TesTabs® make "Wet in the City" an...
Cyanide is used in many chemical and refining processes. It is found in effluent from electroplating and metal cleaning operations, coke ovens, steel manufacturing facilities, and gas scrubbers. Although cyanide can be safely removed by alkaline chlorination, its acute toxicity to aquatic life...
VISOCOLOR Powder Pillows Sulfate reagent set for photometric determination of Sulfate. Ideal for drinking water and waste water samples. Measuring range: 15 - 200 mg/L SO42-
Standard test for the determination of Ozone. Reagent kit for highly sensitive photometric measurements with low costs per sample. Pre-programmed on NANOCOLOR photometers. Measuring range: Ozone - 0.01–1.50 mg/L O3
VISOCOLOR Powder Pillows Silica LR reagent set for photometric determination of Silica in the low range. Ideal for boiler feed water analysis of high pressure boilers. Measuring range: 0.02-2.10 mg/L SiO2 Set of Molydate-, Citric acid- and Ascorbic acid reagent
The CHEMetrics accessory is suitable for use with water purification system, which ensures best water quality by resisting airborne contaminants. This accessory is carefully designed with durable construction to ensure optimum performance.
The Legionella Field Test Kit is the most basic of the Legionella Detection test kits. The test is easy and fast — no reagents or interpretation of results required! With results in 25 minutes, the test allows for immediate understanding and response to the water conditions. Regular use will...
Sensitive, safe to use - SenSafe No reagent preparation time Easy to do, quick results These test strips are an excellent alternative to wet chemical chlorine tests. The unique indicator (TMB) is reactive only to free chlorine; therefore, no interference from monochloramines occurs. Accurate,...
The Merckoquant Phosphate Test Kit utilizes a colorimetric method with test strips and reagent to measure phosphate levels in water. It provides a simple and effective way to monitor phosphate concentrations, ensuring environmental and industrial standards are met. This kit is easy to use and offers...