Portable Water Quality Test Kits

Water quality test kits are the most convenient way to perform water quality tests without extensive laboratory equipment. They are invaluable when measuring the pH levels of water, which measures the acidity and alkalinity of the water and is important for assessing if water is suitable for drinking, agricultural, or industrial processes. Monitor the chlorine levels to ensure all water is disinfected correctly and safe for consumption. Some water quality test kits can also identify the presence of harmful bacteria, which are indicators of water contamination and potential health risks.

Portable water testing kits are available in multiple forms, including test strips, chemical reagent kits, and more. Suitable for different types of water sources, including drinking water, pool, or environmental monitoring applications.

In addition to kits, Thomas Scientific also sells water quality test strips.

Portable Water Quality Test Kits

Products (371)

Compare Tool

Select up to 3 products

  • Hydrogen Peroxide CHEMets® Kits, Ferric Thiocyanate Method

    Hydrogen peroxide is a strong oxidizing agent with a variety of uses. Applications include the treating of industrial effluents and domestic waste and serving as a disinfectant in aseptic packaging. For the food and beverage industry, CHEMetrics Hydrogen Peroxide CHEMets® and Vacu-vials®...

  • Chloride Titrets® Test Kits

    Chloride is the most common inorganic anion found in water and wastewater. The Maximum Secondary Contaminant Level for drinking water for chloride is 250 mg/L. Natural sources of salt are the ocean and various salt deposits above and below ground. Chloride is very corrosive to most metals in systems...

  • Dissolved Oxygen Test Kits

    Direct Reading Titrator (9860J75 and J76) For determining dissolved oxygen in natural and treated waters Employs azide modification of Winkler method Range from 0 to 10 ppm with 0.2 ppm sensitivity Sufficient for 50 tests at 10 ppm Ideal for daily monitoring or D.O. meter checkups and backup. EPA...

  • Chloride Test Kits

    EPA-accepted method for NPDWR and NPDES Employs modified APHA Argentometric method Range of 0 to 50 ppm Cl in 1 ppm increments Sufficient for 50 tests Range of 0 to 200 ppm Cl in 4 ppm increments Sufficient for 50 tests at 200 ppm Employs Argentometric method

  • Chloride Test Kit

    Contents: 30 mL Hydrogen Peroxide 3% 30 mL Chloride Reagent A 30 mL Sulfuric Acid, 0.5N 15 mL Phenolphthaein Indicator 0.5% 2 x 30 mL Silver Nitrate 0.171 N 1 Sample Tube, 5-10-25 mL w/ cap  

  • R2A Agar

    Hardy Diagnostics

    R2A Agar is recommended for enumeration of heterotrophic bacteria in water, especially potable water. This product is not intended to be used for the diagnosis of human disease.

  • Test Kit Components

    Direct Reading Titrator, Syringe Type For use in LaMotte field titration kits as well as in standard laboratory procedures such as dilutions and solution dispensing Plunger and barrel of propionate plastic; barrel has Luer slip tip Capacity 1 mL   All-purpose test tube used primarily with...

  • Ammonia CHEMets® Kits, Direct Nesslerization Method

    Low-level ammonia nitrogen may be naturally present in water as a result of the biological decay of plant and animal matter. Higher concentrations in surface waters can indicate contamination from waste treatment facilities, raw sewage, industrial effluents (particularly from petroleum refineries),...

  • Phosphate CHEMets® Kits

    Phosphorus occurs naturally in rock formations in the earth's crust, usually as phosphate. High phosphate concentrations in surface waters may indicate fertilizer runoff, domestic waste discharge, or the presence of industrial effluents or detergents. Although phosphates from these sources are...

  • Ozone CHEMets Kit

    Ozone is a strong oxidizing agent and is used as an alternative to chlorine as a biocide in the disinfection of drinking water. Ozone is used to remove odor, decolorize, and to control algae and other aquatic growths. Ozone is also used in various disinfectant and sterilization processes in the food...

  • Aquafast II Chlorine Dioxide, Tablets

    Test kit chemistries are convenient-to-use tablets. Rapidly dissolving, long shelf-life, tablets allow chemistry to be added to sample without reagent loss.

  • NANOCOLOR COD 160 Hg-free

    Tube test for the determination of COD. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: COD - 15–160 mg/L O2

  • MColortest™ Color-matching vessel Hydrazine for 108017

    The MColortest Color-matching vessel is specifically designed for hydrazine detection in water using test kit 108017. It provides a reliable and accurate method for comparing color changes during the testing process. With its clear and precise design, it facilitates easy observation and...

  • Spectroquant® Phenol Test Method: photometric

    UN Number: UN3316

  • NANOCOLOR Copper

    CTL Scientific

    Standard test for the determination of Copper. Reagent kit for highly sensitive photometric measurements with low costs per sample. Pre-programmed on NANOCOLOR photometers. Measuring range: Copper - 0.01–10.0 mg/L Cu²?

  • Phosphonate Test Kit

    7625 CAS Dropper Pipet Sufficient for 50 tests at 20 ppm 1 drop = 1.25 ppm HEDP 1 drop = 1.4 ppm PBTC Chromazurol S method may be used for Dequest, Bayhibit, Belcor 575 and Belsperse 161 phosphonates. Indicator changes from yellow to pink at the pH ideal for the reaction, then thorium nitrate is...

  • NANOCOLOR Vicinal Diketones

    Tube test for the determination of Vicinal diketones. Precise rapid tests for all kind of water and waste water analysis. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Diacetyl - 0.015–0.600 mg/kg Diacetyl

  • Iron (Total & Ferrous) Vacu-vials Kit

    Iron is present in nature in the form of its oxides, or in combination with silicon or sulfur. The soluble iron content of surface waters rarely exceeds 1 mg/L, while ground waters often contain higher concentrations. The National Secondary Drinking Water Standard for iron is 0.3 mg/L, as iron...

  • NANOCOLOR Easily Liberated Cyanide 04

    Tube test for the determination of easily liberated cyanide. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Cyanide - 0.01–0.40 mg/L CN?

  • Sulfide CHEMets® Kits

    Sulfides are naturally present in ground waters as a result of leaching from sulfur-containing mineral deposits. Surface waters do not usually contain high sulfide concentrations. Sulfides result from the decomposition of organic matter, from bacterial sulfate reduction under anaerobic conditions...

  • StormWatch MS4 Water Screening Kit

    The LaMotte Stormwater MS4 Kit has instrumentation and reagent systems to provide a preliminary screening of stormwater outflow, and to determine whether it is contributing to the overall pollutant load from precipitation events. Meets guidance as set forth by USEPA. Features Fast: Most tests can be...

  • MQuant™ Calcium, Test Method: colorimetric with test strips and reagents

    Method: colorimetric with test strips and reagents 10 - 25 - 50 - 100 mg/l Ca 2+ MQuant™ UN Number: UN3316 Storage class: 5.1B Oxidizing hazardous materials Storage: Store at +2°C to +8°C. Hazard: Corrosive The calcium test is suitable for rapid determination of calcium in aqueous...

  • NANOCOLOR Cyanide 08

    CTL Scientific

    Tube test for the determination of Cyanide. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Cyanide - 0.02–0.80 mg/L CN?

  • NANOCOLOR Ammonium 10

    CTL Scientific

    Tube test for the determination of Ammonium. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Ammonium - 0.2–8.0 mg/L NH4-N, Ammonium - 0.2–10.0 mg/L NH4?

Compare Tool

Select up to 3 products