Lab Glassware

Lab Glassware

Products (321)

Compare Tool

Select up to 3 products

  • Reflux Apparatus, Continuous, Fuchs

    Continuous reflux apparatus keeps solvents pure and free of oxygen. Compact, upright design allows multiple units to be assembled in small areas. Distillation column is 250mm long, vacuum jacketed, unsilvered. Allihn condenser is 250mm. Adapter at top has two hose connections for maintaining inert...

  • Adapter, Offset

    Offset adapter with outer joint top, inner joint bottom. Some include drip tip. Ace Glass's Offset Adapter is designed to provide flexibility in glass joint systems by allowing for offset connections. This adapter is made from superior glass material, ensuring it can withstand various chemical...

  • Adapter, Connecting Hose

    Adapter with bent hose connection top and standard taper inner bottom joint. This connecting hose adapter is an essential tool in various lab applications where secure and efficient fluid or gas transfer is required. It is designed to fit seamlessly between two pieces of glassware, ensuring a...

  • Sparger, Easy action stopcock

    Sparger tube with Ace fritted bottom available in various porosities. Top has either 0-3 or 0-5 Easy Action Stopcock. The 90 degree side arm is available with a glass hose connection or a #7 Ace-Thred which promotes the use of our 5853-06 Ace-Safe conn

  • Glass Distillation Column, Vacuum jacketed

    Large distillation columns, jacketed with internal expansion bellows. Outer jacket baked out and evacutaed to 10-6 Torr. Columns are silvered internally with observation stripe. All columns are supplied with the proper number of bellows to withstand the 180 Deg C temperature differential at all...

  • Arsine Generators, Improved

    For arsine analysis using the diethyldithicarbamate (SDDC) colorimetric method. Design also meets specifications of ACS/USP, EPA and can be used with APHA Standard 104A. Apparatus is compact, requires less set-up time and eliminates the ball and socket connection normally used. Complete item...

  • Adapters, Inert Gas, Inner Joint

    Adapter has two hose connections 180° from one another to permit a flow of inert gas over the apparatus. Hose connection has an O.D. of 10mm at the largest serration.

  • Distillation Apparatus, Trap-to-Trap

    Used for the removal of solvents or other volatiles by vacuum distillation at ambient temperature. When used with Schlenk reaction Vessel, No. 7756, the trap prevents excessive loss of solution in the event of a bump. The distillate is collected in a No. 9477 pear shaped flask or other suitable...

  • Solid-glass beads borosilicate

    For use as distillation column packing, mixing beads, and boiling stones. Each 454 g box has a packing volume of approx. 360 cm3. +/-10% variation in bead size.

  • Spherical Joints, Ball Members

    Made to ASTM Specifications E677. Spherical joints, ball members, are essential components for assembling laboratory glassware systems. They provide a robust and versatile connection, allowing for multi-directional movement and flexibility in setup configuration. Made from high-quality borosilicate...

  • Synthware Vacuum Adapters with Glass Stopcocks, 90°

    Synthware vacuum adapter with a serrated hose connection turned 90 degrees to the standard taper inner joint. The glass stopcock has a 2 mm bore and is used to regulate the flow of gasses or liquids into reaction systems.

  • Adapter, Nylon or PTFE, NPT, Tubing to Ace-Thred

    This bushing adapter has a male Ace-Thred connection at bottom and a female NPT thread drilled into the center of the top of the bushing. The top FNPT connection matches male Swagelok fittings and facilitates joining plastic or metal tubing to Ace-Thred glass fittings and adapters. This adapter is...

  • Synthware Rotary Evaporator Anti-Splash Traps

    Trap is placed between the vapor tube and the evaporation flask. This design prevent possible contamination in the event of bumping. With upper outer and lower inner standard taper joints.

  • Adapters, Distillation, 105°

    Distillation adapter with sealed in lower drip tip and top outer joints, both being the same size.

  • Specialty Joints

    Standard taper inner and outer lengths tooled on longer lengths or different sizes than normally available under part numbers CG-100 through CG-105. These joints offer the glassblower the opportunity to construct apparatus made of heavier tubing or without unnecessary seals.

  • Adapter, Bushing

    Bushing type adapter for standard taper joints. Smaller outer or female joint is within the larger male joint.

  • Reducing Tee, Process Pipe

    Process pipe reducing tee. Designed for high-performance and reliable operation, this Reducing Tee for process piping offers a versatile solution for complex pipeline systems. Constructed with precision, it allows for secure connections between three pipes of differing diameters. This component is...

  • Synthware Kjeldahl Distilling Trap Adapters

    Adapter is placed above flask to prevent carry-over of reactions which have a tendency to foam. With top outer and lower inner standard taper joints.

  • SYNTHWARE Hickman-Hinkle Still Head with Side Port

    Hickman-Hinkle Still Head, with Side Port, Synthware, Joint: 14/10, for microscale fractional distillation, supplied with one compression cap, one Viton O-ring and one PTFE-faced silicone septum.

  • Distilling Column, Hemple

    Plain distillation column with a row of indentations to support column packing material. Column length listed is for the straight portion above the row of indentations and below the joint. Column has a standard taper top outer and lower inner joint.

  • Adapter, Spherical to Standard Taper

    Transition adapter to convert a spherical ball or socket 2 joint to a standard taper inner joint. The Spherical to Standard Taper Adapter allows for the integration of spherical joints with standard taper glassware. It provides a reliable connection, expanding the versatility of your laboratory...

  • Distilling Receiver, Moisture Test, Barrett

    Similar to CG-1261 but with the uptake tube vacuum jacketed to improve distillation performance. The jacket eliminates the possibility of condensation or recrystallization of distillate in the sidearm.

  • Adapters, Inlet, Inner Joint, 90°

    Allows for flexible tubing to be connected to apparatus for introduction of vacuum or pressure. Hose connection has an O.D. of 10mm at the largest serration and is bent downward at a 90º angle to the inner joint.

  • Adapter, Twin, Ace-Thred

    Twin adapter features two Ace-Thred top openings and a standard taper inner joint bottom. With the supplied nylon bushings, two tubes or a thermometer and bleed tube can be inserted through the same joint. The 24/25 medium length joint is compatible wi

Compare Tool

Select up to 3 products