Gas Chromatography Columns

Gas Chromatography Columns

Products (255)

Compare Tool

Select up to 3 products

  • Column GC Cap High Efficiency HP-1ms  20m, 0.18mm, 0.18um

    100% Dimethylpolysiloxane Non-polar Low bleed characteristics Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked and solvent rinsable Agilent Technologies products are intended for sale/shipment within the US only. International customers should...

  • Rtx-5MS—Low-Bleed GC-MS Columns (fused silica)

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles. Column specifically tested for low-bleed performance. Temperature range: -60°C to...

  • SPB®-5 Capillary GC Column L × I.D. 30 m × 0.53 mm, df 1.50 µm

    Application: This non-polar general purpose column provides primarily a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. USP Code: This column meets USP G27 and G36 requirements. Phase: Bonded Poly(5% diphenyl/95% dimethyl siloxane) Temp. Limits:...

  • CYDEX-B Capillary Columns

    Permethylated Beta Cyclodextrin (Chiral) Separation of Chiral Compounds Application Areas: Separation of enantiomeric compounds found in natural products Operating Temperature: 30°C to 220/240°C Suitable Replacement for: Cyclodex-B, Rt-BDEXm

  • SCOT Capillary GC Column phase Bentone 34/DNDP

    Supelco is the leader in Support Coated Open Tubular (SCOT) GC column technology. Our unsurpassed manufacturing technique allows us to deposit a uniform layer of liquid phase-coated support particles on the inner wall of stainless steel tubing. This technology gives us access to many phases that are...

  • Chromatography Reservoirs with Spherical Joints & Reservoirs

    General purpose column having a PTFE stopcock, reservoir of the listed capacity and a top spherical socket joint. Glass wool (not supplied) is used to support the column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by...

  • DB-200

    Agilent Technologies

    (35% Trifluoropropyl)-methylpolysiloxane 300/320°C temperature limit Midpolarity (more polar than DB-1701 or DB-17) Ideal for difficult to separate positional isomers Unique interactions with compounds containing nitro, halogen and carbonyl groups Low ECD bleed Unique selectivity Close...

  • Rtx-5 Amine Columns (fused silica)

    low-polarity phase; Crossbond 5% diphenyl/95% dimethyl polysiloxane Active basic compounds that otherwise require derivatization, or an alternative analytical technique, can be analyzed on an Rtx-5 Amine column. The tubing surface is chemically altered to reduce tailing of basic compounds,...

  • DB-FFAP 30m, .32mm, .25um, 5" Cage

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Nitroterephthalic acid modified polyethylene glycol High polarity Temperature range from 40 to...

  • Rt-Alumina BOND/Na2SO4 Columns (fused silica PLOT)

    Restek Rt-Alumina BOND columns are highly selective for C1–C5 hydrocarbons and separate all saturated and unsaturated hydrocarbon isomers above ambient temperatures. The reactivity of the aluminum oxide stationary phase is minimized, by deactivation with inorganic salts like KCl or...

  • DB-5 And DB-5ms

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-5 (2713R99, T86, T94 and V89) (5%-Phenyl)-methylpolysiloxane Non-polar Excellent general...

  • Metal Packed GC Column (General Configuration) phase none, matrix 60/80 Molecular Sieve 5A support

    In packed columns, the carrier gas percolates through the porous bed. In a packed column, separation is achieved by moving the solutes apart. Packed columns are made up of two main materials; stainless steel and Pyrex glass. Metal packed columns are more suitable for long and high carrier gas flow...

  • GC GS-Q-30m-Megabore, .53m, 5" Cage

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Porous divinylbenzene homopolymer A PLOT column with polarity between Porapak-Q and Porapak-N...

  • HP-5ms

    Agilent Technologies

    Meets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked Solvent...

  • DB-1ms

    Agilent Technologies

    100% Dimethylpolysiloxane Identical selectivity to DB-1 Non-polar Very low bleed characteristics, ideal for GC/MS Improved acid performance compared to standard 100% Dimethylpolysiloxane columns Improved signal-to-noise ratio for better sensitivity and mass spectral integrity 340°/360°C...

  • BP5MS Capillary Columns

    5% Phenyl Polysilphenylene-siloxane High temperature General Purpose GC column - suitable for over 80% of all routine analyses performed by gas chromatography Very Low Bleed - ideal for trace analysis Non-Polar Extremely inert Ideal for GC-MS Application Areas: Ultra trace analyses,...

  • J&W DB-1ms Ultra Inert Capillary GC Columns

    DB-1ms is an excellent general-purpose GC column and ideal for GC/MS of active analytes commonly found in drug screening and environmental analyses. The Ultra Inert 1ms GC columns set the new industry standards for consistent column inertness and exceptionally low column bleed. These columns allow...

  • DB-Waxetr

    Agilent Technologies

    Polyethylene glycol (PEG) Extended Temperature Range (etr) High polarity Excellent column-to-column repeatability Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G16 Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax,...

  • Rtx-35 Columns (fused silica)

    midpolarity phase; Crossbond diphenyl dimethyl polysiloxane An Rtx-35 column is a popular confirmation column for pesticides and herbicides in conjunction with an Rtx-5 or Rtx-1701 column. The higher phenyl content causes useful elution order and retention time changes. General-purpose columns for...

  • Capillary Column Ferrules

    Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS Transferlines...

  • Chromatography Columns with Rodaviss® Joints

    General purpose column having a PTFE stopcock and a top Rodaviss® outer joint. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC CHEMISTRY 43, 2923 [1978], and covered in U.S. Patent Number...

  • Capillaries for electrophoresis

    Untreated capillaries Recommended application: Capillary electrophoresis Preparation of capillary columns Capillary LC applications

  • Column GC Cap High Efficiency DB-1ms 20m, 0.18mm, 0.18um

    The DB-1ms is a non-polar, low bleed column with excellent inertness for acids/bases and an extended upper temperature limit. Using low bleed stationary phases reduces the column contribution to background noise resulting in a higher signal to noise ration and better sensitivity. The reduced column...

  • GS-Q

    Agilent Technologies

    Porous divinylbenzene homopolymer A PLOT column with polarity between Porapak-Q and Porapak-N Separates ethane, ethylene and ethyne (acetylene) Not recommended for quantification of polar compound Minimal conditioning time required — 1 hour Temperature limits: -60° to 250°C GS-Q has...

Compare Tool