Gas Chromatography Columns

Gas Chromatography Columns

Products (255)

Compare Tool

Select up to 3 products

  • HP-Plot Q

    Agilent Technologies

    Bonded polystyrene-divinylbenzene based column A PLOT column with polarity between Porapak-Q and Porapak-N Column for C1 to C3 isomers and Alkanes to C12, CO2 , methane, air/CO, oxygenated compounds, sulfur compounds and solvents A PLOT column to replace packed gas-solid...

  • Column Nuts

    Agilent Technologies

    Agilent MS interface column nuts (or transfer line nuts) are manufactured from a softer metal than the transfer line interface. This is to prevent stripping of the transfer line threads and costly repairs. Add a few MS interface column nuts to your next order and keep spares on hand. Agilent...

  • DB-5.625

    Agilent Technologies

    Equivalent to a (5%-Phenyl)-methylpolysiloxan Non-polar Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols* Surpasses EPA performance criteria for semivolatiles Inert for base, neutral and acidic compounds High temperature limit with...

  • Chromatography Columns with Standard Taper Joints, Reservoirs & Fritted Discs

    Similar to CG-1196 but with a COARSE porosity sealed in fritted disc to support column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC...

  • GC Columns Ferrules

    Agilent Technologies

    The Agilent Technologies ferrule is compatible for use with GC (gas chromatography) columns. It is mainly used to safeguard columns and maintain leak proof connections during high temperature applications. This accessory is made of sturdy material which offers enhanced durability. This product is...

  • SLB®-5ms Capillary GC Column

    Application: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles,...

  • Column GC Cap High Efficiency HP-5 20m, 0.18mm, 0.18um

    (5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limit Bonded and cross-linked; solvent rinsable Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to...

  • DB-Wax

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature...

  • Elite-5MS capillary column 30m x 0.25mm, 0.25µm

    Temperature range -60oC to 350 oC Equivalent to USP G27, G36 phases

  • Rtx-BAC2 Columns (fused silica)

    proprietary Crossbond phase These columns separate to baseline all blood alcohol compounds in blood, breath, or urine, in less than 3 minutes, under isothermal conditions. Isothermal analysis increases productivity by eliminating the need for oven cycling. Confirmation is easily achieved with this...

  • Stabilwax-DB Columns (fused silica)

    polar phase; Crossbond base-deactivated Carbowax polyethylene glycol—for amines and basic compounds Stabilwax-DB columns reduce adsorption and improve responses for many basic compounds, without analyte derivatization or column priming. For different selectivity of basic compounds, or higher...

  • HP-FFAP

    Agilent Technologies

    Nitroterephthalic acid modified polyethylene glycol High polarity Temperature range from 40 to 250°C Designed for the analysis of volatile fatty acids and phenols Replaces OV-351 Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 Similar Phases: Stabilwax-DA, HP-FFAP,...

  • GC Instruments Parts & Supplies

    The Agilent Technologies accessory is used in GC (gas chromatography) equipment, which is used in analytical chemistry experiments to determine chemical components from sample mixture. This accessory ensures smooth and reliable performance of the GC instrument. This product is only available to U.S....

  • LPGC Rtx-5ms Column Kit, 0.32 mm ID

    3.3x faster multiresidue pesticides analysis in foods with 76% less helium consumption. Factory-coupled, leak-free kit makes setup as simple as a column change. Ideal for speeding up GC-MS and GC-MS/MS methods. Restek’s low-pressure GC column kits have been specifically designed to easily...

  • MXT-1 Columns (Siltek-treated stainless steel)

    nonpolar phase; Crossbond dimethyl polysiloxane MXT-1 columns exhibit long lifetime and very low bleed at high operating temperatures. A proprietary synthesis process eliminates residual catalysts that could cause degradation and increase bleed. General-purpose columns for solvent impurities, PCB...

  • SCOT Capillary GC Column phase TCEP

    Supelco is the leader in Support Coated Open Tubular (SCOT) GC column technology. Our unsurpassed manufacturing technique allows us to deposit a uniform layer of liquid phase-coated support particles on the inner wall of stainless steel tubing. This technology gives us access to many phases that are...

  • Rt-Msieve 5A Columns (fused silica PLOT)

    Restek’s molecular sieve 5A PLOT columns are designed for efficient separation of argon/oxygen and other permanent gases, including carbon monoxide. Special coating and deactivation procedures ensure chromatographic efficiency and the integrity of the porous layer coating. Molecular sieves...

  • SolGel-WAX Capillary Columns

    Polyethylene Glycol (PEG) in a Sol-Gel matrix World's highest temperature wax phase Bonded polyethylene glycol Very robust high-temperature column Less susceptible to damage by oxygen than conventional wax phases Polar phase Low bleed and inert Application Areas: Recommended for highly active...

  • DB-Petro 100m, .25mm, 0.5um, 5"Cage

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Configured for the analysis of petroleum process products PONA, PIANO...

  • GS-Alumina

    Agilent Technologies

    Most “polar” Alumina phase Aluminum oxide with proprietary deactivation Excellent general use column for light hydrocarbon analysis: C1 to C8 hydrocarbon isomers Separates C1-C4 saturated and unsaturated hydrocarbons Best for resolving cyclopropane from propylene Faster, more efficient...

  • Stx-CLPesticides2 Columns (fused silica with Siltek deactivation)

    proprietary Crossbond phase Many laboratories analyzing organochlorine pesticides struggle with breakdown and adsorption of endrin, DDT, and methoxychlor caused by active sites throughout the analytical system. Siltek passivation technology enables these columns to offer unsurpassed inertness and...

  • CP-Al2O3/Na2SO4 Columns

    Agilent Technologies

    CP-Al2O3/Na2SO4 has a polar surface to separate ppm levels of C1-C5 hydrocarbons in a main stream of C1-C5 hydrocarbons. Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place...

  • Inlet Ferrules, High Purity Graphite

    Chromatography Research Supplies

    Thomas Scientific offers a large selection of ferrules made from PTFE, Graphite, Vespel® and Vespel/Graphite composites. Ferrule sizes refer to the size of the fittings into which they fit; they are not the diameter of the ferrule. (For example, 1/16" ferrules are 1/8" diameter.)...

  • SPB®-20 Capillary GC Column

    Application: This column has intermediate polarity due to the higher (20%) phenyl content, producing a different elution order of polar compounds for confirmational information. It is often used for analyses of aromatic analytes. USP Code: This column meets USP G32 requirements. Phase: •Bonded...

Compare Tool

Select up to 3 products