Gas Chromatography Columns

Gas Chromatography Columns

Products (255)

Compare Tool

Select up to 3 products

  • SP™-2560 Capillary GC Column, L × I.D. 100 m × 0.25 mm, df 0.20 µm

    Synonym: SP-2560, 100M.20UM.25MM Application This highly polar biscyanopropyl column was specifically designed for detailed separation of geometricpositional (cis/trans) isomers of fatty acid methyl esters (FAMEs). It is extremely effective for FAME isomer applications. USP Code : This column meets...

  • DB-2887 10m, 0.53mm, 3.00um

    Agilent Technologies

    100% Dimethylpolysiloxane Specifically designed for simulated distillation using ASTM Method D2887 Rapid conditioning, fast run time and low bleed when compared to packed columns Bonded and cross-linked Solvent rinsable Similar Phases: HP-1, Petrocol EX2887, MXT-2887, MXT-1 This product is only...

  • Rxi-1ms Columns (fused silica)

    nonpolar phase; Crossbond dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of...

  • HP-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C for =2.0 µm...

  • DB-HeavyWAX GC Columns

    Agilent Technologies

    The Agilent J&W DB-HeavyWAX Polyethylene Glycol (PEG) is a high temperature WAX column that can operate at higher maximum temperatures compared to standard WAX columns. The higher maximum temperature limit allows for shorter run times, providing a lower cost per test. The column provides...

  • SCOT Capillary GC Column phase BMEA

    Supelco is the leader in Support Coated Open Tubular (SCOT) GC column technology. Our unsurpassed manufacturing technique allows us to deposit a uniform layer of liquid phase-coated support particles on the inner wall of stainless steel tubing. This technology gives us access to many phases that are...

  • DB-1ht

    Agilent Technologies

    100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and cross-linked Solvent rinsable Similar Phases: Stx-1ht Agilent...

  • Hydroguard-Treated MXT Guard/Retention Gap Columns/Transfer Lines (passivated stainless steel)

    Extend analytical column lifetime by preventing degradation from harsh "steam-cleaning" water injections Maximum temperature: 325°C When transfer lines from purge-and-trap systems, air monitoring equipment, or other instruments carry condensed water vapor, deactivated column tubing...

  • Carbowax 20m And HP-20m

    Agilent Technologies

    Polyethylene glycol, MW 20,000 Equivalent to USP Phase G16 Similar Phases: DB-WAX, HP-INNOWax, DB-WAXetr Because the Carbowax 20M and the HP-20M are not bonded or cross-linked, we do not recommend solvent rinsing. DB-WAX is the recommended bonded alternate for the HP-20M. Agilent Technologies...

  • SolGel-1ms Capillary Columns

    100% Dimethyl Polysiloxane in a Sol-Gel matrix A robust, inert, high temperature, non-polar phase for use with mass spectrometers. Highly Inert Less Bleed - Better MS library identification Less bleed - Less ion source maintenance Less Bleed - Better sensitivity Can also be used for all non-MS...

  • Chromatography Columns with Rodaviss® Joints & Fritted Discs

    Similar to CG-1192 but with a sealed in COARSE porosity fritted disc to support column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC...

  • Duraguard Columns

    Agilent Technologies

    Columns with “built in” guard columns, no press-fit connectors Minimize front-end contamination and increase column lifetime Aid in focusing sample onto the front of the column for better peak shape Minimize MSD contamination originating from the column (when used in transfer line)...

  • BP5 Capillary Columns

    5% Phenyl / 95% Dimethyl Polysiloxane Excellent general purpose GC column Low bleed Non-polar High temperature Application Areas: Aromatics, pesticides, herbicides, drugs of abuse, hydrocarbons, GC/MS applications Operating Temperatures: 0.25-1.5µm film thickness: -60°C to 320/340°C...

  • LPGC Rxi-624Sil MS Column Kit, 0.53 mm ID

    1.8x faster analysis of nitrosamines with 29% less helium consumption. Factory-coupled, leak-free kit makes setup as simple as a column change. Ideal for speeding up GC-MS and GC-MS/MS methods. Restek’s low-pressure GC column kits have been specifically designed to easily install into your...

  • HP-1

    Agilent Technologies

    100% Dimethylpolysiloxane Industry standard general purpose column Non-polar Wide range of applications Superior performance of low molecular weight alcohols High temperature limit Bonded and cross-linked Solvent rinsable Wide range of column dimensions Equivalent to USP Phase G2 Applications...

  • HP-FFAP

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Nitroterephthalic acid modified polyethylene glycol High polarity Temperature range from 60 to...

  • Retention gaps

    MACHEREY-NAGEL

    The retention gap technique in combination with on-column injection allows concentration of a large sample volume in the capillary column. Choice of the retention gap depends on the solvent used: the flooded zone after injection should be between 20–30 cm/µL Me-Sil retention gap only for...

  • PERMABOND® Silane Capillary Columns

    PERMABOND® Silane GC capillary columns for silane analyses Features Developed especially for the analysis of monomeric silanes and chlorosilanes (not for the separation of trimethylsilyl derivatives) Also suited for the separation of dimeric siloxanes and silazanes Columns with 0.32 mm ID: Max....

  • GC Capillary Column

    Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is only...

  • DB-1701p

    Agilent Technologies

    Low/midpolarity Exact replacement of HP-PAS1701 Specifically designed and processed for the analysis of organochlorine pesticides ECD tested to assure minimal pesticide breakdown and low ECD bleed Bonded and cross-linked Solvent rinsable Similar Phases: SPB-1701, CP-Sil 19CB, Rtx-1701, BP-10,...

  • Deactivated Fused Silica Tubing

    Deactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness. Agilent Technologies products are intended for sale/shipment...

  • DB-VRX

    Agilent Technologies

    Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA Methods 502.2, 524.2 and 8260 0.45 mm ID columns provide more plates per meter compared to 0.53 mm ID columns for the fewest coelutions for GC method (an industry first)** No subambient cooling required to resolve...

  • Rtx-20 Columns (fused silica)

    low- to midpolarity phase; Crossbond diphenyl dimethyl polysiloxane Rtx-20 polymer is synthesized to exacting standards. All residual catalysts and low molecular weight fragments are removed from the polymer, providing a tight monomodal distribution and extremely low bleed. General-purpose columns...

  • GC Capillary Guard Column

    Agilent Technologies

    J&W DB-5ms is a non-polar phenyl arylene polymer gas chromatography (GC) Column, virtually equivalent to (5%-phenyl)-methylpolysiloxane, featuring an excellent signal-to-noise ratio for analytical applications. This improved performance gives better sensitivity and mass spectral integrity, and...

Compare Tool