Gas Chromatography Columns

Gas Chromatography Columns

Products (255)

Compare Tool

Select up to 3 products

  • Chromatography Columns with Standard Taper Joints

    General purpose column has a PTFE stopcock and a top outer joint. Glass wool (not supplied) is used to support column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia...

  • Graphite/Vespel® Ferrules

    Your chromatography analysis does not end with the selection of the GC column. The combination of components selected for your instrument also make an important contribution to successful separations. Choose SGE technology to improve your chromatography.

  • DB-17ms

    Agilent Technologies

    Virtually equivalent to (50%-Phenyl)-methylpolysiloxane 320°/340°C upper temperature limit Very low bleed midpolarity, suitable for GC/MS Exhibits inertness to active compounds Enhanced mass spectral integrity Bonded and cross-linked Solvent rinsable Best column for CLP pesticides Similar...

  • Tenax Packing Materials

    Tenax Packing Materials

  • BPX50 Capillary Columns

    50% Phenyl Polysilphenylene-siloxane Mid polarity Inert Low bleed High temperature Ideal for a range of EPA methods and pharmaceutical applications Application Areas: EPA methods 604, 608, 8060, 8081, triazines/herbicides, drug screening, steroids and a variety of pharmaceutical applications...

  • Rtx-1 Columns (fused silica)

    nonpolar phase; Crossbond dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates. Long...

  • CAM

    Agilent Technologies

    Base deactivated polyethylene glycol Specifically designed for amine analysis Excellent peak shape for primary amines Replaces HP-Basicwax Similar Phases: Stabilwax-DB, Carbowax Amine Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing. Agilent Technologies products...

  • Rtx-1701 Columns (fused silica)

    midpolarity Crossbond phase Rtx-1701 is one of the more popular stationary phases used in capillary GC. The mix of cyano and phenyl functional groups increases the polarity and offers a different elution order relative to less polar Rtx-1 or Rtx-5 columns. An Rtx-1701 column is ideal for...

  • HP-Ms

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Identical selectivity to HP-5 Non-polar Very low bleed...

  • Chromatography Reservoirs with Spherical Joints, Reservoirs & Fritted Discs

    Similar to CG-1202 but with a COARSE porosity fritted disc sealed into the lower end of the column for packing support. Column is constructed using MEDIUM WALL tubing. Can be used with CG-1201 flow controller. Connection between the column and flow control adapter are spherical joints connected with...

  • HP-Chiral

    Agilent Technologies

    Beta-cyclodextrin in (35%-Phenyl)-methylpolysiloxane Chiral separations without chiral specific derivatization Phenyl-based polymer provides low bleed and does not interfere with nitrogen-specific detectors. Available in two concentrations of beta-cyclodextrin: 10% and 20% 20% beta-cyclodextrin best...

  • Cyclodex-B

    Agilent Technologies

    10.5% Beta-Cyclodextrin in DB-1701 Chiral separations without chiral specific derivatization Broad range of resolving potential Excellent peak shape Similar Phases: LIPODEX C, Rt-β DEXm, β -DEX 110, β -DEX 120 Because Cyclodex-B GC columns are not bonded or cross-linked, Agilent does...

  • Se-30 And Se-54

    Agilent Technologies

    SE-30: 100% Dimethylpolysiloxane SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane Because SE series GC columns are not bonded or cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact...

  • Rtx-DHA Columns (fused silica)

    Crossbond 100% dimethyl polysiloxane—optimized for hydrocarbon analysis Gasolines are complex mixtures of hundreds of compounds. Information about concentrations of the individual components is important for evaluating raw materials and for controlling refinery processes. ASTM D6730-01...

  • Chromatography Columns with Standard Taper Joints & Reservoirs

    General purpose column having a PTFE stopcock, reservoir of the listed capacity and a top standard taper outer joint. Glass wool (not supplied) is used to support the column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as...

  • Stabilwax-MS Columns (fused silica)

    Stabilwax-MS columns ensure reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels! Ideal for food and flavor analysis (e.g., essential oils), fragrance...

  • BPX-VOLATILES Capillary Columns

    Cyanopropylphenyl Polysiloxane Polar phase EPA volatile organics analysis (EPA 624, 502.2, SW-846 8240/8260) Application Areas: Environmental analyses, volatile organics, alcohol analysis, USP G43 Operating Temperature: 1.0-3.0µm film thickness: 0°C to 290/300°C Suitable Replacement...

  • DB-624 Ultra Inert GC Columns

    Agilent Technologies

    DB-624 Ultra Inert columns are designed for trace analysis in environmental volatile organic compound applications. Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for...

  • LPGC Rxi-35Sil MS Column Kit

    3.3x faster analysis of arylamines with 81% less helium consumption. 1.4x faster analysis of phthalates with 67% less helium consumption. Factory-coupled, leak-free kit makes setup as simple as a column change. Ideal for speeding up GC-MS and GC-MS/MS methods. Restek’s low-pressure GC column...

  • Ultra 1 & Ultra 2

    Agilent Technologies

    Ultra 1: 100% Dimethylpolysiloxane Ultra 2: (5%-Phenyl)-methylpolysiloxane Non-polar Bonded and cross-linked Solvent rinsable HP-1 and HP-5 with tighter specifications for retention index and capacity factors Temperature range: -60° to 325°/350°C Recommended for use with Sadtler...

  • DB-PS1 15m, 0.53mm, 0.15um

    Agilent Technologies

    Excellent inertness Virtually unbreakable Available in a wide variety of stationary phases Bonded and cross-linked Ideal for high temperature analysis and process applications Our asy to handle DB-ProSteel metal columns are deactivated with a new formula (this is not glass lined steel) to provide...

  • Rtx-CLPesticides2 Columns (fused silica)

    proprietary Crossbond phase Improved resolution and faster analyses, compared to 1701 or phenyl phases, make these the pesticide columns of choice. Rtx-CLPesticides columns are specially designed to overcome the coelutions and analyte breakdown typically encountered in chlorinated pesticide analyses...

  • Rxi-17Sil MS Columns (fused silica)

    midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column characteristics...

  • Rxi-624Sil MS Columns (fused silica)

    midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column characteristics...

Compare Tool

Select up to 3 products