Gas Chromatography Columns

Gas Chromatography Columns

Products (255)

Compare Tool

Select up to 3 products

  • GC Capillary Column

    Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is only...

  • BPX90 Capillary Columns

    90% Cyanopropyl Polysilphenylene-siloxane Unique bonded phase Highly Polar Thermally Stable Application areas: ideal for fast separation of fragrances, aromatics, petrochemical, pesticides, PCBs and isomers of Fatty Acid Methyl Esters (FAMEs) Operating temperatures: 0.25-0.50µm film thickness:...

  • OPTIMA® d-3 Capillary Columns

    OPTIMA® δ-3 Capillary columns for GC Features Polysiloxane phase with autoselectivity USP G49 Medium polar without CN groups Analytes determine the polarity of the phase Autoselectivity resulting in a polarity range from approximately the nonpolar OPTIMA® 5 to the midpolar OPTIMA®...

  • SUPELCO Omegawax® Capillary GC Column

    L × I.D. 30 m × 0.32 mm, df 0.25 μm Synonym(s): Amino Acid Sequence: Empirical Formula: Formula Weight: Linear Formula: Purity: Boiling Point: Melting Point: Density: Refractive Index: Storage: Beilstein Registry Number: Components: RTECS No.: RIDADR:

  • DB-17ht

    Agilent Technologies

    (50%-Phenyl)-methylpolysiloxane Midpolarity Extended upper temperature limit of 365°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Improved resolution for triglycerides Ideal for confirmational analyses Bonded and...

  • ShinCarbon ST Columns

    Analyze oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide with one column at room temperature. ShinCarbon ST material, a high surface area carbon molecular sieve (~1,500 m 2 /g), is the ideal medium for separating gases and highly volatile compounds by gas solid chromatography (GSC)....

  • Hp Blood Alcohol Analysis Column

    Reliable blood alcohol analysis Excellent confirmation column with DB-ALC2 for method using t-butanol as internal standard Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place...

  • SPB®-624 Capillary GC Column
  • Rtx-BAC1 Columns (fused silica)

    proprietary Crossbond phase These columns separate to baseline all blood alcohol compounds in blood, breath, or urine, in less than 3 minutes, under isothermal conditions. Isothermal analysis increases productivity by eliminating the need for oven cycling. Confirmation is easily achieved with this...

  • Column GC Cap High Efficiency HP-5ms 20m, 0.18mm, 0.18um

    (5%-Phenyl)-methylpolysiloxane Non-polar Low bleed characteristics, ideal for GC/MS First-rate inertness for active compounds including acidic and basic compounds Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked; solvent rinsable Agilent...

  • Column GC Cap High Efficiency HP-1 20m, 0.18mm, 0.18um

    100% Dimethylpolysiloxane Non-polar Superior performance of low molecular weight alcohols (less than C5) High temperature limit (325/350°C upper limit) Bonded and cross-linked; solvent rinsable This product is only available to U.S. Domestic Customers. Agilent Technologies products are intended...

  • CP-Wax 58 FFAP CB Capillary Columns

    Agilent J&W CP-Wax 58 FFAP CB column is a nitroterephthalic acid-modified, chemically bonded polyethylene glycol phase. It is designed for the analysis of acidic compounds, such as phenols, and underivatized as well as derivatized free fatty acids. Nitroterephthalic acid-modified polyethylene...

  • DB-FFAP

    Agilent Technologies

    Nitroterephthalic acid modified polyethylene glycol High polarity Designed for the analysis of volatile fatty acids and phenols Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 Temperature limits: 40° to 250°C NOTE: Agilent does not recommend the use of water or...

  • LPGC Rxi-624Sil MS Column Kit, 0.32 mm ID

    2.3x faster analysis of nitrosamines with 67% less helium consumption. 2.3x faster analysis of alkylfurans with 72% less helium consumption. Factory-coupled, leak-free kit makes setup as simple as a column change. Ideal for speeding up GC-MS and GC-MS/MS methods. Restek’s low-pressure GC...

  • HP-5ms Ultra Inert

    Agilent Technologies

    Agilent J&W HP-5ms Ultra Inert is specifically tested for inertness for active compounds, including acidic and basic compounds, to meet the worldwide drive for lower detection levels. With very low bleed characteristics, bonded and cross-linked HP-5ms Ultra Inert is solvent rinsable and ideal...

  • Rxi-5ms Columns (fused silica)

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this...

  • DB-210

    Agilent Technologies

    (50%-Trifluoropropyl)-methylpolysiloxane High polarity Excellent for U.S. EPA Methods 8140 and 609 Bonded and cross-linked Solvent rinsable Exact replacement of HP-210 Close equivalent to USP Phase G6 Similar Phases: SP-2401 Agilent Technologies products are intended for sale/shipment within the US...

  • Rt-QS-BOND Columns (fused silica PLOT)

    porous divinylbenzene homopolymer Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic...

  • Rtx-624 Columns (fused silica)

    low- to midpolarity phase The unique polarity of the Rtx-624 column makes it ideal for analyzing volatile organic pollutants. Although the Rtx-502.2 column is recommended in many methods, the Rtx-624 column offers better resolution of early eluting compounds. The Rtx-624 phase produces greater than...

  • BPX1 Capillary Columns

    100% Dimethyl Polysiloxane Non-polar column Dimensionally stabilized phase Low bleed Specifically designed for high temperature hydrocarbon analysis Ideal for simulated distillation Application Areas: ASTM methods D2887 and D6532 Operating Temperature: Polyimide Clad:  0.1-0.9µm film...

  • SPB®-5 Capillary GC Column L × I.D. 30 m × 0.25 mm, df 0.25 µm

    eCl@ss 32119290 Application: This non-polar general purpose column provides primarily a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. USP Code: This column meets USP G27 and G36 requirements. Phase: Bonded Poly(5% diphenyl/95% dimethyl...

  • HP-1ms

    Agilent Technologies

    100% Dimethylpolysiloxane Identical selectivity to HP-1 Non-polar Low bleed characteristics General purpose column Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked Solvent rinsable Temperature range: -60° to 325°/350°C Applications...

  • SPB®-35 Capillary GC Column

    material fused silica  Quality Level 100 Agency meets requirements for USP G42 parameter 0-300 °C temperature (isothermal or programmed) Beta value 250 df 0.25 μm technique(s) gas chromatography (GC): suitable L × I.D. 30 m × 0.25 mm  matrix...

  • DB-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP Phase G27 Similar Phases: HP-5, Ultra-2, SPB-5,...

Compare Tool

Select up to 3 products