  • MXT-Q-BOND Columns (Siltek-treated stainless steel PLOT)

    Advantages of metal MXT PLOT columns include: Can be made in small coil diameters—perfect for tight spaces. Rugged material withstands rough handling and shock. Designed for robust performance in process GCs and field instruments. Available in 3.5"-coil diameter or 7"-diameter,...

  • Rt-Q-BOND Columns (fused silica PLOT)

    100% divinylbenzene Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic peak. The Q-BOND...

  • D3606 Application Column Set

    Conforms to the specifications established in the current ASTM method D3606 for the quantitation of benzene and toluene in spark ignition fuel containing ethanol. Complete resolution of benzene from ethanol—no compromising coelutions. Accurate quantification of benzene and toluene. Column sets...

  • Rtx-1301 (G43) Columns (fused silica)

    low- to midpolarity phase Many analysts feel the Rtx-1301 column has the best cyanosiloxane bonded stationary phase available, with no other column manufacturer providing lower bleed, longer lifetime, or better inertness. Our polymer is fully characterized to ensure long-term reproducibility,...

  • Rtx-CLPesticides Column Kit

    Application-specific columns for organochlorine pesticides and herbicides. Low bleed—ideal for high sensitivity GC-ECD or GC-MS analyses. Baseline separations in less than 10 minutes. Stable to 320–340°C Analyze EPA Method 8081B, 8082A, 8151A, 504.1, 515, 508.1, and 552.2 compounds...

  • OPTIMA® 1 Capillary Columns

    OPTIMA® 1 Capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase Separation of components according to boiling points Thick film columns ≥ 3 µm film are expecially recommended for solvent analysis. Low bleed columns with equal selectivity...

  • DB-35ms

    Agilent Technologies

    Virtually equivalent to a (35%-Phenyl)-methylpolysiloxane Midpolarity Very low bleed characteristics Extended temperature limit of 340/360°C Exhibits inertness to active compounds Suitable for confirmational analysis Bonded and cross-linked Solvent rinsable Replaces HP-35ms Close equivalent to...

  • HP-Pona

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Configured for the analysis of petroleum process products Tested to...

  • Rxi-1HT Columns (fused silica)

    nonpolar phase; dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column...

  • DB-Dioxin

    Agilent Technologies

    Specifically engineered for the analysis of polychlorinated dibenzodioxins (PCDDs) and dibenzofurans (PCDFs) Resolves 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in one run Low bleed Bonded and cross-linked Solvent rinsable Similar Phases: SP-2331, 007-23, Rtx-2332, CP-Sil 88 100 psi...

  • BP10 Capillary Columns

    14% Cyanopropylphenyl Polysiloxane Ideal for organochlorine pesticides analysis Highly Inert Low bleed Application Areas: Environmental analyses (EPA methods 608 and 8081), pesticides/herbicides, drugs of abuse, pharmaceuticals Operating Temperature: 0.25-0.5µm film thickness: -20°C to...

  • BPX5 Capillary Columns

    5% Phenyl Polysilphenylene-Siloxane High temperature General Purpose GC column - suitable for over 80% of all routine analyses performed by gas chromatography Very Low Bleed - ideal for trace analysis Non-Polar Extremely inert Ideal for GC-MS Application Areas: Ultra trace analyses,...

  • Metal Packed GC Column (fits Agilent, Configuration "A")

    An economical metal column should be used for less demanding applications where the inertness of glass is not required. This column fits Agilent 5880, 5890, 6890, 7820, and 7890 (configuration A, on-column injection, all detectors except TCD). Application The carrier gas percolates through the...

  • Rxi-35Sil MS Columns (fused silica)

    midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column characteristics...

  • DB-225

    Agilent Technologies

    (50%-Cyanopropylphenyl)-dimethylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Bonded and cross-linked Solvent rinsable Exact replacement of HP-225 Close equivalent to USP Phase G7 Similar Phases: SP-2330, CP-Sil 43 CB, Rtx-225, BP-225,...

  • Column GC Cap High Efficiency DB-5.265 20m, 0.18mm, 0.18um

    Equivalent to (5%-Phenyl)-methylpolysiloxane Non-polar Specially processed to exhibit excellent inertness for EPA Semivolatile Methods 625, 1625, 8270 and CLP protocols Surpasses EPA performance criteria for semi-volatiles Inert and neutral for base, neutral and acidic compounds High temperature...

  • Column GC Cap High Efficiency DB-35ms 20m, 0.18mm, 0.18um

    Virtually equivalent to a (35%-Phenyl)-methylpolysiloxane Midpolarity Very low bleed characteristics Extended temperature limit of 340/360°C Excellent inertness for active compounds Ideal for conformational analyses Bonded, cross-linked and solvent rinsable Agilent Technologies products are intended...

  • DB-1301 And DB-1701

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-1301: (6%-Cyanopropyl-phenyl) methylpolysiloxane DB-1301: Equivalent to USP Phase G43...

  • DB-MTBE

    Agilent Technologies

    Low polarity stationary phase Resolves MTBE from 2-methylpentane and 3-methylpentane for better quantitation Engineered for purge and trap injection without the need for cryofocusing Bonded and cross-linked Solvent rinsable Agilent Technologies products are intended for sale/shipment within the US...

  • Chromatography Columns with Standard Taper Joints & Fritted Discs

    Similar to CG-1188 but with a sealed in COARSE porosity fritted disc to support column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC...

  • BPX70 Capillary Columns

    70% Cyanopropyl Polysilphenylene-siloxane High temperature Custom designed for separation of Fatty Acid Methyl Esters (FAMEs) Industry standard column for FAME analysis Ideal for cis/trans isomer separation Polar phase Long operating life Application Areas: Fatty acid methyl esters, carbohydrates,...

  • Stx-CLPesticides Columns (fused silica with Siltek deactivation)

    proprietary Crossbond phase Many laboratories analyzing organochlorine pesticides struggle with breakdown and adsorption of endrin, DDT, and methoxychlor caused by active sites throughout the analytical system. Siltek passivation technology enables these columns to offer unsurpassed inertness and...

  • DB-17

    Agilent Technologies

    (50%-Phenyl)-methylpolysiloxane Midpolarity slightly more polar than HP-50+ Suitable for confirmational analyses Bonded and cross-linked Solvent rinsable Temperature limits are 40° to 260/280°C or 40° to 280/300°C Equivalent to USP Phase G3 HP-50+, Rtx-50, CP-Sil 24 CB,...

  • Hp Blood Alcohol Analysis, 5" Cage

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Reliable blood alcohol analysis Excellent confirmation column with DB-ALC2 for method using...