  • Stabilwax Columns (fused silica)

    polar phase; Crossbond polyethylene glycol Restek’s polar-deactivated surface tightly binds the Carbowax polymer and increases thermal stability, relative to competitive columns. Because of the increased stability produced by the bonding process, Stabilwax columns exhibit long column...

  • Ultimate Unions

    Agilent Technologies

    Extend the life of your analytical GC or GC/MS column by using a guard column reliably connected to you analytical column with our high performance capillary GC column connector, the Ultimate Union. New-technology Ultimate Union kits eliminate the “arts and crafts” involved in connecting...

  • OPTIMA® 5 MS Capillary Columns

    OPTIMA® 5 MS Capillary columns for GC Features 5 % diphenyl – 95 % dimethylpolysiloxane USP G27 / G36 Nonpolar phase with low bleeding Suited for GC/MS and ECD application and general analyses at trace level Perfect inertness for basic compounds Similar phases: DB-5, HP-5 MS, Ultra-2,...

  • Select PAH Capillary Columns

    Agilent Technologies

    Agilent J&W Select PAH is the first capillary column that provides a single solution for PAH analysis by separating all the isomers, thereby avoiding false positives and inaccurate results. It provides easy, fast, and accurate quantification of PAHs in environmental and food samples by resolving...

  • GS-Gaspro

    Agilent Technologies

    Bonded PLOT column technology Suitable for light hydrocarbons and sulfur gas Retention stability not affected by water Separates CO and CO2 on a single column Ideal PLOT column for CG/MS - no particles Temperature limits: -80° to 260°/300°C Similar phase: CP-Silica PLOT...

  • DB-502.2

    Agilent Technologies

    Available in 105 meters for volatiles analyses Excellent peak shape Bonded and cross-linked Solvent rinsable Similar Phases: Rtx-502.2, VOCOL, HP-VOC Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent...

  • Rt-Alumina BOND/CFC Columns (fused silica PLOT)

    Restek Rt-Alumina BOND columns are highly selective for C1–C5 hydrocarbons and separate all saturated and unsaturated hydrocarbon isomers above ambient temperatures. The reactivity of the aluminum oxide stationary phase is minimized, by deactivation with inorganic salts like KCl or...

  • OPTIMA® 5 Capillary Columns

    OPTIMA® 5 Capillary columns for GC Features 5 % phenyl – 95 % methylpolysiloxane · USP G27, G36 Nonpolar standard phase with large range of application Low bleed columns with equal selectivity see OPTIMA® 5 MS, ultra low bleed columns see OPTIMA® 5 MS Accent Similar phases:...

  • Stabilwax-DA Columns (fused silica)

    polar phase; Crossbond acid-deactivated Carbowax polyethylene glycol—for acidic compounds Stabilwax-DA bonded polyethylene glycol has an acidic functionality incorporated into the polymer structure. This permits analysis of acidic compounds without derivatization, significantly reduces...

  • Rtx-CLPesticides Column Kits

    Improved resolution and faster analyses, compared to 1701 or phenyl phases, make these the pesticide columns of choice. Rtx-CLPesticides columns are specially designed to overcome the coelutions and analyte breakdown typically encountered in chlorinated pesticide analyses for EPA Methods 8081, 608,...

  • DB-VRX 60m, .25mm, 1.4um, 5"Cage

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA Methods...

  • DB-624

    Agilent Technologies

    Specifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent rinsable...

  • SLB®-5ms Capillary GC Column

    Application: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles,...

  • DB-608

    Agilent Technologies

    Specifically designed for the analysis of chlorinated pesticides and PCBs U.S. EPA Methods: 608, 508, 8080 Excellent inertness and recoveries without pesticide breakdown Bonded and cross-linked Solvent rinsable Exact replacement of HP-608 Similar Phases: SPB-608, NON-PAKD Pesticide, 007-608 Agilent...

  • DB-Tph 30m, 0.32mm, 0.25um

    Agilent Technologies

    Specifically designed for the analysis of total petroleum hydrocarbons (TPHs), soil analysis, and LUFT Three analyses in one injection: gas range organics, diesel range organics and motor oil Fast run time Bonded and cross-linked Solvent rinsable Agilent Technologies products are intended for...

  • HP-1

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column - “Industry Standard” Wide...

  • Particle Traps For Use With Plot Columns

    Though highly stabilized, it is impossible to guarantee that no particles will dislodge from the column wall. When used in valve-switching applications, the use of a particle trap can prevent the scarring of rotors. Agilent Technologies products are intended for sale/shipment within the US only....

  • Press-Fit Capillary Column Connectors

    In the past it was necessary to use Press-fit connectors with specific dimensions to connect columns of those dimensions. Modern Press-fit connectors are “laser-milled” to provide highly reproducible taper angles throughout the length of the Press-fit insuring an excellent seal. Now the...

  • LPGC Rxi-17Sil MS Column Kit

    2.0x faster analysis of MCPDs with 69% less helium consumption. Factory-coupled, leak-free kit makes setup as simple as a column change. Ideal for speeding up GC-MS and GC-MS/MS methods. Restek’s low-pressure GC column kits have been specifically designed to easily install into your GC-MS or...

  • Elite 624 capillary column 30m x 0.53mm, 3.00µm

    Temperature range -20°C to 240°C Equivalent to USP G43 phase

  • GC Capillary Column

    Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is only...

  • HP-35

    Agilent Technologies

    (35%-Phenyl)-methylpolysiloxane Midpolarity - slightly less polar than DB-35 Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, DB-35, BPX-35 Agilent Technologies products are...

  • HP-INNOWax GC Columns

    Agilent Technologies

    HP-INNOWax is a polyethylene glycol (PEG) stationary phase that features high polarity and high upper temperature limits. It is a close equivalent to USP phase G16 and is targeted at food, flavor, and fragrance applications. The improved line of Agilent J&W HP-INNOWax GC columns utilizes the...

  • GS-Alumina KCl

    Agilent Technologies

    Least “polar” Alumina phase Aluminum oxide deactivated with KCl Good choice for light hydrocarbon analysis Good resolution of propadiene and butadiene from ethylene and propylene streams Similar Phases: CP-Al2O3/KCl PLOT, Rt-Alumina PLOT, Alumina PLOT,...