Octet Comparator For determining zinc in cooling waters Octet Comparator has color standards representing 0, 1, 2, 3, 4, 6, 8 and 10 ppm zinc Employs buffered zincon reagent system Sufficient for 50 tests
LaMotte's Direct Reading Titrator offers an innovative approach to titration, enabling direct reading of results without the need for additional calculations. This device simplifies the titration process, making it accessible for users with varied expertise levels. Its compact design allows for easy...
Tube test for the determination of COD. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: COD-50–300 mg/L O2
The Iodine test papers are a convenient way to test Iodine in water with fast results. Range and sensitivity is 0, 30, 60, 120, 180 ppm.
Hexavalent chromium salts are used in numerous industrial processes. They are also used extensively as corrosion inhibitors in open and closed cooling water systems. The Diphenylcarbazide Method References: APHA Standard Methods, 22nd ed., Method 3500-Cr B - 2009. ASTM D 1687-02, Chromium in Water,...
LaMotte calcium hardness reagent - 30 mL is a liquid reagent for swimming pool water testing. LaMotte Liquid Reagent is a versatile solution for various water quality testing applications. This reagent is formulated to deliver accurate and reliable results, ensuring precise analysis. Its liquid form...
QUANTOFIX Multi stick for aquarium owners are the semi-quantitative test strips for the determination of the total hardness (Ca 2+ , Mg 2+ ), carbonate hardness (HCO 3 -, CO 3 2-) and the pH value of aquarium water. Measuring range: 0-6.3-12.5-18.8-25.0-31.3 °e (total hardness)...
Tube test for the determination of Formaldehyde. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Formaldehyde - 0.1–8.0 mg/L
QUANTOFIX Sulphate semi-quantitative test strips for the determination of sulphate in solutions. Measuring range: 200->400->800->1200- >1600 mg/L SO42-
Tube test for the determination of Peroxide. Precise rapid tests for all kind of water and waste water analysis. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Peroxide - 0.03–2.00 mg/L H2O2
Tube test for the determination of Nickel. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Nickel - 0.10–7.00 mg/L Ni²?
Method: colorimetric with test strips and reagents 10 - 25 - 50 - 100 - 250 mg/l Al MQuant™ UN Number: UN1814 Storage class: 8B Non-combustible, corrosive hazardous materials Storage: Store at +15°C to +25°C. Hazard: Corrosive Aluminium compounds are used as precipitating agents...
The test measures both ammonium ions and dissolved ammonia in e.g. groundwater and surface water, seawater, drinking water and aquarium water.
Tube test for the determination of Sulfate. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Sulfate - 200–1000 mg/L SO4²?
Tube test for the determination of Manganese. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Manganese - 0.1–10.0 mg/L Mn
Tube test for the determination of Detergents. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Detergents - 0.3–15.0 mg/L Triton® X-100
Test water sample for alkalinity, ammonia, biochemical oxygen demand, chloride, copper, hardness, iron, nitrate, dissolved oxygen, pH, and phosphate. Kit contains enough materials to perform 10 tests.
Low-level ammonia nitrogen may be naturally present in water as a result of the biological decay of plant and animal matter. Higher concentrations in surface waters can indicate contamination from waste treatment facilities, raw sewage, industrial effluents (particularly from petroleum refineries),...
Aquaquant® Nitrite Test Method: colorimetric with colour card and comparator block with long test tubes
UN Number: UN3316
Come in a 60 mL quantity, this performance check standard is for inspection and monitoring water quality.
Use Thermo Scientific™ Orion™ AQUAfast Tablet Reagents with Orion™ AQUAfast colorimeters and Thermo Scientific™ Orion™ AquaMate Vis and UV-Vis spectrophotometers. These convenient, rapidly dissolving tablets can be precisely added to samples without leaving residual...
The Insta-Test Total Chlorine/pH/Hardness and Iron test kit combines the best of both worlds. The kit includes 25 quick, easy and accurate tests using a simple dip-and-read formulation. The strips are packaged in a unique hinged, waterproof PopTop bottle with a desiccant liner that protects the test...