  • CHROMABOND® PS

    MACHEREY-NAGEL

    Polymer-based SPE phases for RP and ion chromatography Features Base material: high purity polystyrene-divinylbenzene copolymers (PS/DVB), pore size 100 Å, particle size 100 µm very low degree of swelling, thus very well suited for chromatography reliable function over the whole pH range...

  • NANOCOLOR COD 60000

    MACHEREY-NAGEL

    Tube test for the determination of COD. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: COD - 5–60.0 g/L O2

  • PH-FIX  4.5-10 - box of 100 strips

    pH-Fix 4.5-10.0 indicator strips with chemically bound indicators are the bench mark for pH testing with test strips. The fixation prevents bleeding and therefore contamination of the sample. measuring range: pH 4.5-5.0-5.5-6.0-6.5- 7.0-7.5-8.0-8.5-9.0-9.5-10.0

  • NANOCOLOR COD 1500, Hg-free

    Tube test for the determination of COD. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: COD - 100–1500 mg/L O2

  • QUANTOFIX Peracetic Acid 500-100 strips

    QUANTOFIX Peracetic acid 500 semi-quantitative test strips for the determination of peracetic acid. Measuring range: 0-50-100-200-300-400- 500 mg/L

  • NANOCOLOR COD 10000

    MACHEREY-NAGEL

    Tube test for the determination of COD. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range COD - 1.00–10.00 g/L O2, COD - 1000–10000 mg/L O2

  • NANOCOLOR Ortho and Total Phosphate LR 1

    Tube test for the determination of ortho- and total Phosphate. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Phosphate (ortho) - 0.05–0.50 mg/L P , Phosphate (ortho) - 0.2–1.5...

  • PEHANON pH 7.2-8.8 - box of 200 strips

    Pehanon pH 7,2 - 8,8 test strips unify pH indicator and reference color chart on one strip. Any sample color has the same effect on both, the reference colors and the reactive pad, allowing unadulterated pH reading even in colored solutions. measuring range: 7.2-7.4-7.6-7.8-8.0-8.2-8.5-8.8

  • NANOCOLOR Anionic Surfactants 4

    Tube test for the determination of Detergents. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Detergents - 0.20–3.50 mg/L SDS , Detergents - 0.20–4.00 mg/L MBAS

  • CHROMAFIL® PES Syringe Filters

    CHROMAFIL® syringe filters – Ideal for GC, HPLC and UHPLC sample filtration By using CHROMAFIL® syringe filters unwanted particles are removed which can otherwise cause contamination and clogging of sensitive instrumentation. So, filtering your samples leads to an increase of lifetime...

  • TRITEST pH 1-11 Dispenser

    Tritest pH 1 - 11 indicator paper has three different indicator zones on a single paper. The three zones guarantee optimal color differences and safe determination of in-between values. measuring range: 1-2-3-4-5-6-7-8-9-10-11

  • LIPODEX® Capillary Columns

    LIPODEX® cyclodextrin phases Capillary columns for GC enantiomer separation Features Base material: cyclic oligosaccharides consisting of six (α-cyclodextrin), seven (β-cyclodextrin) or eight (γ-cyclodextrin) glucose units bonded through α-1,4-linkages Regioselective...

  • Alox Aluminium Oxide Layers for TLC

    Aluminium oxide, specific surface (BET) ~ 200 m 2 /g, mean pore size 60 Å; inert organic binder indicator manganese-activated zinc silicate available as glass plates, POLYGRAM® polyester sheets and ALUGRAM® aluminium sheets Recommended application: terpenes, alkaloids, steroids,...

  • NANOCOLOR Chromate

    MACHEREY-NAGEL

    Standard test for the determination of Chromium / Chromate. Reagent kit for highly sensitive photometric measurements with low costs per sample. Pre-programmed on NANOCOLOR photometers. Measuring range: Chromium / Chromate - 0.01–3.0 mg/L , Chromium / Chromate - 0.01–6.0 mg/L CrO4²?

  • NUCLEOSHELL® HILIC HPLC Columns

    NUCLEOSHELL® core-shell silica phases for HPLC NUCLEOSHELL® Core-shell technology provides Better resolution at lower back pressure and shorter retention time Solid core of silicon dioxide Homogeneous shell of porous silica Highest efficiency compared to traditional totally porous materials...

  • NANOCOLOR Phenolic Index 5

    Tube test for the determination of Phenols. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Phenols - 0.2–5.0 mg/L Phenol

  • POLYGOSIL® Irregular silica, Octadecyl phases

    POLYGOSIL® Irregular silica phases for LC, C18 (ODS) modified for reversed-phase (RP) applications Features Irregular silica for analytical application, pH stability 2–8 Available pore sizes 60, 100, 300 and 1000 Å Available particle sizes 5 µm, 7 µm and 10 µm

  • QUANTOFIX EDTA - box of 100 strips

    QUANTOFIX EDTA semi-quantitative test strips for the rapid and easy analysis of EDTA directly on-site. Measuring range: 0-100-200-300-400 mg/L

  • Magnetic crimp caps, N 20

    Septa are assembled, caps are ready-to-use. Enhance your laboratory's efficiency with the use of these high-quality magnetic crimp caps, N 20. These caps are specifically designed to provide a secure seal for your vials or bottles, ensuring the integrity of the contents and reducing the risk of...

  • OPTIMA® 5 MS Capillary Columns

    OPTIMA® 5 MS Capillary columns for GC Features 5 % diphenyl – 95 % dimethylpolysiloxane USP G27 / G36 Nonpolar phase with low bleeding Suited for GC/MS and ECD application and general analyses at trace level Perfect inertness for basic compounds Similar phases: DB-5, HP-5 MS, Ultra-2,...

  • PEHANON pH 8.0-9.7 - box of 200 strips

    Pehanon pH 8,0 - 9,7 test strips unify pH indicator and reference color chart on one strip. Any sample color has the same effect on both, the reference colors and the reactive pad, allowing unadulterated pH reading even in colored solutions. measuring range: 8.0-8.2-8.4-8.6-8.8-9.1-9.4-9.7

  • Nano-SIL DIOL Diol-Modified HPTLC Silica Layers

    Features Base material: nano silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å specific pore volume 0.75 mL/g particle size 2–10 μm pH stability 2–8 Indicator: acid-resistant product with a pale blue fluorescence for short-wave UV (254 nm) UV-absorbing substances...

  • QUANTOFIX Total Iron 1000-100 strip box

    QUANTOFIX Total iron 1000 semi-quantitative test strips for rapid and easy analysis of Iron directly on-site. Measuring range: 0-5-20-50-100-250- 500-1000 mg/L Fe2+/Fe3+

  • Chlorine test paper - 5 meter roll

    Chlorine test reel is particularly suitable for high range applications in disinfectant solutions which are for example used in food and beverage industry and animal farms.