Solid Phase Extraction (SPE) Columns

Solid Phase Extraction (SPE) columns are essential tools in sample preparation, widely used for isolating analytes from complex matrices. These columns facilitate efficient purification, making them indispensable in various fields, including environmental testing, pharmaceuticals, and food safety.

SPE columns with high-quality sorbent materials to ensure precise separation and consistent results. Advanced features include a wide range of sorbent chemistries, catering to different application needs, and robust construction that prevents channeling and ensures uniform flow rates.

The practical benefits of these features are clear: improved accuracy in analyte detection, reduced sample preparation time, and minimized solvent usage. SPE columns streamline workflows, providing reliable and reproducible outcomes.

Available in various sizes and formats, including standard SPE tubes, these columns offer flexibility to match specific sample volumes and requirements. Whether you need small-scale extractions or larger batch processes, there is an SPE column to meet your needs.

For added convenience, many SPE columns are compatible with automated systems and come with accessories like adaptors and collection plates, ensuring seamless integration into your laboratory setup.



We also provide lab chromatography columns at Thomas Sci.

Compare Tool

Select up to 3 products

1 - 32 of 157
Sort
View
Show
Discover the Deal

 

  • MACHEREY-NAGEL

    Features More than 50 different sationary phases available e.g., silica gel based: unmodified, C8, C18, NH2, CN; Polyermic material: HR-X, HLB, PA; mixed-mode, special combinations, aluminum oxide, kieselguhr (XTR) etc. NP, RP, ion exchanger and for special applications Different…

  • Avantor - J.T.Baker®

  • Retention Mechanism: Reversed-phase and anion-exchange Sample Matrix Compatibility: Organic or aqueous solutions •Dual layer SPE tube that contains both Supelclean ENVI-Carb (upper layer) & PSA (lower layer) SPE sorbents (separated by PE frit) •Developed to offer superior clean up when conducting…

  • Sep-Pak Accell Plus QMA Plus Light cartridges contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of…

  • PS/DVB copolymer with secondary and tertiary ammonium modification for mixed-mode SPE with weak anion exchange and reversed-phase properties (WAX). Exchange capacity ≥ 0.8 meq/g, pKa 6 + 9. High-purity material with ideal flow properties and highest reproducibility. Allows highest…

  • MACHEREY-NAGEL

    Special silica phase for SPE enrichment of drugs from urine or plasma Features Base material silica, pore size 60 Å, particle size 45 µm, specific surface 500 m2/g, pH stability 2–8 special bifunctional modification - C8 / SA (strong cation exchanger –…

  • MilliporeSigma

    Synonyms: SPE Reservoir

  • MACHEREY-NAGEL

    Polystyrene-divinylbenzene adsorbent resin for SPE Features Highly porous polystyrene-divinylbenzene copolymer specific surface 1200 m2/g, particle size 50–100 μm very high binding capacity, up to 30 % of adsorbent weight (for comparison: silica adsorbents about 3 %) …

  • Agilent Technologies

    Ensures fast, reliable extraction of anionic compounds Inert to a wide variety of solvents Stable for pH ranges 0 - 14 Water-wettable The Agilent SampliQ Strong Anion Exchange (SAX) polymeric resin is a mixed-mode, tertiary amine-modified divinyl benzene polymer that…

  • Dispersive SPE (dSPE), often referred to as the "QuEChERS" method (Quick, Easy, Cheap, Effective, Rugged, and Safe), is modern sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. Using the QuEChERS method,…

  • quick-ship

    MACHEREY-NAGEL

    Spherical, hydrophobic polystyrene-divinylbenzene resin for SPE Features Hydrophobic polystyrene-divinylbenzene copolymer pH stability 1–14 High-purity material with highest reproducibility and lowest blank values due to an optimized manufacturing process Spherical particles…

  • Agilent Technologies

    Ideal solid phase extraction for melamine analysis Ensures fast, reliable extraction of basic and cationic compounds Resistant to a wide variety of solvents Stable for pH ranges 0 - 14 Water-wettable Agilent's mixed-mode SampliQ SCX polymeric resin is a…

  • Empore membrane SPE technology comprises of SPE particles tightly enmeshed within a network of inert PTFE fibrils (90% SPE particles : 10% PTFE, by weight). The SPE-membrane fabrication process results in a highly dense and uniform extraction medium that offers distinct advantages over traditional…

  • Polar sorbent, used primarily to adsorb analytes from non polar solvents like hydrocarbons, chloro- or flouro-substituted hydrocarbons or less polar esters and ethers.

  • Retention Mechanism: Reversed-phaseSample Matrix Compatibility: Aqueous solutions (drinking, ground, waste water) •Polymerically bonded, octadecyl (17% C), endcapped •Excellent for cleaning, extracting and concentrating pollutants from aqueous environmental samples •Higher 17% C loading for…

  • MACHEREY-NAGEL

    Kieselguhr phase for liquid-liquid extraction Features Base material coarse-grained kieselguhr (also known as diatomaceous earth, hydromatrix, celite) large pore size, high pore volume, constantly high batch-to-batch quality pH working range 1–13 Application: …

  • Ideal for Flash separations from 10 mg up to 300 g Features For convenient operation and reliable upscaling the complete program of ready-to-use Flash cartridges for the Isco Companion® and other Teledyne Isco CombiFlash® systems, or as stand-alone version for all…

  • MACHEREY-NAGEL

    Quaternary ammonium modified silica anion exchanger for SPE (SAX) Features Base material silica, pore size 60 Å, particle size 45 µm, specific surface 500 m2/g, pH stability 2–8 silica modified with quaternary amine strongly basic anion exchanger (capacity ~ 0.3…

  • Supelclean(TM) LC-18 SPE tube is used in the extraction of nonpolar to moderately polar analytes from aqueous samples. Legal Information: Supelclean is a trademark of Sigma-Aldrich Co. LLC

  • Use to close Luer port. Polypropylene. Synonyms: Luer Plugs & Caps

  • Sep-Pak Accell Plus QMA Vac cartridges contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of larger…

  • MACHEREY-NAGEL

    Special silica phase for determination of pesticides in food samples Features Base material silica, pore size 60 Å, particle size 45 μm, specific surface 500 m2/g, pH stability 2–8 Primary and Secondary Amine functions (PSA), 5 % C Removes polar compounds (e.g.,…

  • Solid phase extraction apparatus uses glass vials or tubes for sample collection and concentration. Some sorbents require large desorption volume than small SPE cartridges in such case SPE tubes were used. Application: Empty polypropylene SPE tube with PE frits was used in preparing…

  • HybridSPE-Phospholipid technology is a simple and generic sample prep platform designed for the gross level removal of endogenous protein and phospholipid interferences from biological plasma and serum prior to LC-MS or LC-MS/MS analysis. Biological plasma or serum is first subjected to protein…

  • With Speedisk columns, you can choose the column that works best with your sample size and performance requirements. Patented laminar configuration: reduces run time, increases capacity, eliminates filtration and evaporation steps Columns fit into all popular processors and racks …

  • Connecting kits for CHROMABOND® Flash columns CHROMABOND® Flash Starter Kit consists of: 1/8" PTFE tubing, ID 1.5 mm, length 3 m; 5 x 1/4"-28 PP nuts; 5 x 1/8" ETFE ferrules; 5 x 1/4"-28 nylon unions; 2 x 1/4"-28 PP luer locks female; 1 x 1/4"-28 PP luer…

  • Affinimip SPE is a selective solid phase extraction based upon molecularly printed polymers (MIP). It combines the advantages of Immune-affinity columns in terms of selectivity and a classic solid phase extraction (SPE) in terms of robustness and costs. This selectivity and robustness combines to…

  • Ideal for Flash separations from 10 mg up to 300 g Features For convenient operation and reliable upscaling the complete program of ready-to-use Flash cartridges for the Isco Companion® and other Teledyne Isco CombiFlash® systems, or as stand-alone version for all…

  • The 3 cc Oasis HLB cartridges contain the Oasis HLB sorbent, which is a universal polymeric reversed-phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol. Since the Oasis HLB sorbent is…

  • Combination phase for SPE analysis of PCBs Features SiOH-H2SO4: H2SO4-impregnated silica phase for oxidation of accompanying compounds to ionic and/or polar compounds SA: strongly acidic cation exchanger based on silica with benzene­sulfonic acid modification for removal of ionic…

  • Affinimip SPE is a selective solid phase extraction based upon molecularly printed polymers (MIP). It combines the advantages of Immune-affinity columns in terms of selectivity and a classic solid phase extraction (SPE) in terms of robustness and costs. This selectivity and robustness combines to…

Compare Tool

Select up to 3 products