  • Syringes

    Hamilton

    Gastight syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous...

  • Syringes

    Hamilton

    The Hamilton 1000 series 5 mL syringe features AccuDil® (AD) termination. This syringe model offers borosilicate glass and PTFE fluid path. It can be used at a pressure rating of up to 200 psig and temperature rating of up to 20 to 50 degree C. M8 Threads

  • Syringes

    Hamilton

    The Hamilton 700 series 500 uL syringe is suitable for use with large removable needles. This syringe model offers SST, borosilicate glass fluid path. It can be used at a pressure rating of up to 1000 psig (68.9 bar) and temperature rating of up to 10 to 115 degree C.

  • Syringe 1005Ltnch 5.0ml (22/2"/2)

    Volume 5 mL Syringe Type Gastight Syringe Series 1000 Termination Luer Tip Cemented Needle (LTN) Needle Cemented Needle Gauge 22 gauge Point Style 2 Needle Length 2 inch (51 mm) Needle Inner Diameter 0.0161 inches (0.41 mm) Needle Outer Diameter 0.0283 inches (0.72 mm) Std. Needle Dead Volume 6.81...

  • Pipette Tips

    Hamilton

    Hamilton pipette tips are universal-fit. Hamilton SoftGrip™ Manual Pipettes are used with Hamilton AdvanTip Pipette Tips deliver outstanding accuracy and precision, guaranteed.

  • Inert Valve Hv 1-1

    Actuated Manual   Break Away Torque 15 oz-in (105.9 mNm)   Fluid Path PTFE/CTFE   Housing Material Aluminum   Nominal Port Diameter 0.059 inch (1.5 mm)   Operating Temp (High) 212° F / 100° C   Operating Temp (Low) 50° F / 10° C   Operator Pressure...

  • Needle Assembly

    The Hamilton 32 gauge 18 Inch needle assembly is suitable for use with LASI syringe, which is used in laboratory and research use.

  • Syringes

    Hamilton

    The Hamilton 700 series 10 uL syringe is suitable for use with cemented needles. This syringe model offers SST and borosilicate glass fluid path. It can be used at a pressure rating of up to 2000 psig and temperature rating of up to 10 to 50 degree C.

  • Syringes

    Hamilton

    The Hamilton 1000 series 5 mL syringe features luer tip (LTN) termination. It is suitable for use with cemented needles. This syringe model offers SST, borosilicate glass and PTFE fluid path. It can be used at a pressure rating of up to 200 psig and temperature rating of up to 10 to 50 degree C.

  • Syringes

    Hamilton

    The Hamilton 7000 series 1 uL syringe is suitable for use with special needles. This syringe model offers SST and borosilicate glass fluid path. It can be used at a pressure rating of up to 6000 psig and temperature rating of up to 10 to 115 degree C.

  • Inert Valve Hv 3-3

      Hamilton (HV) Plug Valves provide an economical and flexible method of custom-building a fluid flow control system, from a simple on/off valve to a more complex multi-valve arrangement, using a combination of loop and distribution valves. The small valve body with its chemically inert flow...

  • Luer Lock Needles

    The Kel-F hub is made from CTFE plastic. Needles are available from 31 to 10 gauge. This hub is recommended when connecting to a rigid male Luer like a Luer Tip (LT) syringe because the plastic is more pliable and creates the best seal. All needles are sold in six-packs and the standard needles are...

  • Luer Lock Needles

    The Metal hub is made from nickel plated brass. Needles are available from 33 to 10 gauge. This hub makes the most rigid connection to the needle making it perfect for repetitive septum piercing. Metal hub needles are compatible with PTFE Luer Lock (TLL) syringes. All needles are sold in six-packs...

  • Syringes

    Hamilton

    The Hamilton 600 series 2.5 uL syringe is suitable for use with small removable needles. This syringe model offers SST, borosilicate glass and PTFE fluid path. It can be used at a pressure rating of up to 2000 psig (137.9 bar) and temperature rating of up to 10 to 115 degree C.

  • Flanging Tool Kit

    The Hamilton Flanging Tool Kit was designed to make precise flanges on 12, 18, and 22 AWG FEP (Fluorinated Ethylene-Propylene) tubing. The Flanging Tool Kit may not be suitable for other types of tubing or tubing with different outer or inner diameters. For best results, use only Hamilton premium...

  • Syringes

    Hamilton

    The Hamilton 700 series 100 uL syringe is suitable for use with small removable needles. This syringe model offers SST, borosilicate glass and PTFE fluid path. It can be used at a pressure rating of up to 2000 psig and temperature rating of up to 10 to 115 degree C.

  • Luer Lock Needles

    The Small Hub Removable Needle (RN) is compatible with RN syringes from 2.5 µL to 100 µL. Needles are available from 34 to 18 gauge. All needles are sold in six-packs and the standard needles are 51 mm long. For all custom needles, the length and point style will need to be specified prior to...

  • PROBE ASSY, CONCORDE CT

    PROBE ASSY, CONCORDE CT

  • 1001TPLT 1.0ml SYR,PLNGR TYPE

    Volume 1 mL Volume per rotation 13.23 µL Syringe Type Gastight Syringe Series 1000 Termination Luer Tip (LT) Needle Kel-F Hub Gauge No Needle Included Point Style No Needle Included Needle Length No Needle Included Std. Needle Dead Volume N/A Fluid Path SST, borosilicate glass, PTFE...

  • SampleLock Syringe & Accessories

    The Hamilton plunger assembly is suitable for use with 1001 SampleLock syringe models with LT, LTN, RN, TLL, C barrel terminations. With and without slots

  • HVX Valve

    Hamilton

    The Hamilton 3-2 HVX valve can be threaded with fittings, adapters, male and female luers, FEP tubing assemblies and adapters. With PTFE/CTFE fluid path, this 105.2 uL valve is made of aluminum housing which ensures high strength and durability. It can be operated manually. This valve operates at a...

  • UPGRADE ML600, CONTROL, KIT #1

    The Hamilton UPGRADE ML600, CONTROL, KIT #1 is an essential package for enhancing the functionality of the ML600 system. This kit provides all necessary components for a seamless system upgrade, ensuring improved performance and extended capabilities. Designed with precision engineering, each...

  • Syringes

    Hamilton

    The Hamilton 700 series 10 uL syringe is compatible with small removable needles. This syringe model offers SST and borosilicate glass fluid path. It can be used at a pressure rating of up to 2000 psig and temperature rating of up to 10 to 115 degree C.