Restek

Restek

Products (535)

Compare Tool

Select up to 3 products

  • Unleaded Gasoline (ASTM Class 2 Accelerant)

    Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material. Compound List Unleaded gasoline (8006-61-9)

  • Make Life Easier (MLE) Capillary Tool Kit for Agilent GCs

    Includes: Capillary installation gauge for Agilent GCs Inlet wrench for Agilent GCs Septum nut removal tool 1/8", 3/16", and 1/4" nylon brushes 1/4", 3/8", and 3/16" stainless steel wire tube brushes Stainless steel surface brush 6 stainless steel jet reamers...

  • 1,4-Dioxane

    2,000 μg/mL in P&T methanol

  • 2,4-Dinitrophenol

    Compound List 2,4-Dinitrophenol (51-28-5) Conc. in Solvent and Volume: 1,000 µg/mL in methanol, 1 mL/ampul

  • Standard Mixture of n-alkanes for System Performance Test (16 components)

    For GC analysis of total petroleum hydrocarbons (TPH) in water. Environmentally safer than previous methods. Calibration standard available as diesel #2/motor oil and diesel #2/mineral oil. Compound List (C10) n-Decane (124-18-5) (C12) n-Dodecane (112-40-3) (C14) n-Tetradecane (629-59-4) (C16)...

  • PEEK Tubing

    Features & Benefits Ideal for plumbing to and inside HPLC systems. 1/16" OD in 3- and 10-meter lengths. Less oxygen permeable and more temperature resistant than PTFE or Tefzel tubing. Easily cut to length using Clean-Cut Tubing Cutter (cat.# 25069). Use with PEEK finger-tight or flangeless...

  • Stx-CLPesticides2 Columns (fused silica with Siltek deactivation)

    proprietary Crossbond phase Many laboratories analyzing organochlorine pesticides struggle with breakdown and adsorption of endrin, DDT, and methoxychlor caused by active sites throughout the analytical system. Siltek passivation technology enables these columns to offer unsurpassed inertness and...

  • 508.1 Pesticide Kit

    Compound List 32045: 508 Performance Check Mix δ-BHC (319-86-8), 0.4 µg/mL Chlorothalonil (1897-45-6), 0.5 µg/mL Chlorpyrifos (2921-88-2), 0.02 µg/mL DCPA methyl ester (Chlorthal-dimethyl) (1861-32-1), 0.5 µg/mL 32091: 508.1 Internal Standard Pentachloronitrobenzene...

  • Flexible Stainless Steel Hoses

    With their robust construction and superior flexibility, these stainless steel hoses are designed to handle varying degrees of pressures and temperatures with ease. They offer a reliable solution for transportation of gases or liquids in scientific laboratories, particularly in gas chromatography...

  • Mininert Precision Sampling Valves for Vials

    Mininert valves are very convenient for repetitive sampling and limit content exposure to the silicon septum. Models are available for screw-cap and crimp-top vials. The crimp-top valve for 20 mm ID glassware slides into the neck of the vial. Turn the threaded flange to secure a tight fit.

  • Inserts for 2.0 mL, 11 mm Crimp-Top & 2.0 mL, 9 mm Short-Cap, Screw-Thread Vials

    Restek's inserts for 2.0 mL vials are crafted to optimize sample recovery and reduce waste. They fit both 11 mm crimp-top and 9 mm screw-thread vials, offering versatility across applications. These inserts ensure minimal sample loss, making them suitable for precious or limited samples. Their...

  • Capillary Column Nuts for Agilent 5890/6850/6890/7890 GCs

    Available in brass or stainless steel. Ensure the secure positioning and optimal function of your gas chromatography system with Restek's Capillary Column Nuts. These high-quality, precision-engineered components are designed to fit seamlessly within Agilent 5890, 6850, 6890 and 7890 GC systems,...

  • BTEX Standard (6 components)

    Compound List Benzene (71-43-2) Ethylbenzene (100-41-4) Toluene (108-88-3) m-Xylene (108-38-3) o-Xylene (95-47-6) p-Xylene (106-42-3)

  • Extraction Solvent Stock Solution #2 (2 components)

    Compound List (C10) n-Decane (124-18-5), 20 µL/L (C40) n-Tetracontane (4181-95-7), 20 mg/L

  • Click-On In-Line Super Clean Replacement Gas Traps

    Click-On traps measure: 8 1/2" x 1 1/4" (21.6 x 3.2 cm) Note: Replacement trap only—fittings sold separately.

  • Exempted Drug of Abuse Reference Standards

    Note: Stressed shipping studies indicate that this product remains stable after being continuously exposed to an elevated temperature of 40°C for 7 days. Ground freight is the default shipping method for this product; expedited methods are available upon request.

  • Rocker Vacuum Pumps

    Oil-free vacuum pumps are piston powered, so they do not pollute the air and require minimal maintenance Quiet, low-vibration units keep disturbances to a minimum Built-in thermal protector automatically shuts off pump if it overheats and then restarts it once the unit is cool Inlet filter traps...

  • Ochratoxin A Standard

    Ideal for mycotoxin analyses in cannabis and food testing labs.

  • EPA Method 8061A Phthalate Esters Mixture (15 components)

    Compound List Benzyl butyl phthalate (85-68-7) Bis(2-n-butoxyethyl)phthalate (117-83-9) Bis(2-ethoxyethyl)phthalate (605-54-9) Bis(2-ethylhexyl)phthalate (117-81-7) Bis(2-methoxyethyl)phthalate (117-82-8) Bis(4-methyl-2-pentyl)phthalate (84-63-9) Di-n-butylphthalate (84-74-2) Diethylphthalate...

  • 502.2 Calibration Mix #6

    Conc. in Solvent and Volume: 2,000 μg/mL each in P&T methanol, 1 mL/ampule Min Shelf Life on Ship Date: 6 months Compounds: 4-Chlorotoluene (106-43-4) 1,2-Dichlorobenzene (95-50-1) 1,4-Dichlorobenzene (106-46-7) Hexachlorobutadiene (87-68-3) 4-Isopropyltoluene (p-Cymene) (99-87-6) Naphthalene...

  • Roc™ C8 HPLC Columns (USP L7)

    Roc HPLC columns are built to be the cornerstone for your LC lab. These solid, reliable columns are pressure rated for any 400 bar HPLC system and deliver the peak shape, reproducibility, ruggedness, and performance you demand for all of your conventional HPLC applications. An exceptional value, Roc...

  • 1,3-Butadiene

    Compound List 1,3-Butadiene (106-99-0)

  • Copper Tubing

    Use for plumbing GC systems. Cleaned to remove residual organics.

Compare Tool

Select up to 3 products