Select up to 3 products
The PerkinElmer purge window O-ring is compatible to use with dual view axial purge window.
Concentration: 1,000 µg/mL Matrix: 2% HNO3 Volume: 125 mL Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported at...
The sealed liquid cells have a corrosion-resistant construction making them ideal for highly volatile samples. The sealed liquid cells are ideal for quantitative analysis where you require an accurate reproducible cell thickness. These cells use a lead spacer which is amalgamated to the window...
The PerkinElmer deionizer bag is compatible to use with the NM-H2 plus generator.
Concentration: 1,000 µg/L Matrix: 2% HNO3 Volume: 125 mL Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported at...
Concentration: 1,000 µg/mL Matrix: H2O Volume: 500 mL Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported at ppm...
For use with the 2400 in the CHNmode and with the 2410. pkg. 1
Concentration: 1,000 µg/mL Matrix: H2O Volume: 125 mL Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported at ppm...
Multi-Element Lumina hollow cathode lamp (HCL) for the detection of elemental Aluminum (Al), Calcium (Ca), Copper (Cu), Iron (Fe), Magnesium (Mg), Silicon (Si), Zinc (Zn). Please note that multi-element lamps are not designed to be used in a furnace system. In addition the analysis of Aluminum and...
This torch glassware knurled nit is used with Optima 2x00 DV, 4x00 DV, 5x00 DV, 7x00 DV, and 8x00 ICP-OES series instruments.
Oxygen regulator, two stage HP Brass regulator, SS diaphragm, Delivery Pressure 0-50 PSIG, 1/8 Ultra-Torr Fitting. With CGA 350 fitting.
Tin/Aluminum Capsules must be ordered separately. Kit includes: One Capsule Sealing Unit One Magazine for 4 µL and 30 µL Capsules One Instruction Manual.
For sealing sample vials for temperatures up to 210 °C. Lowbackground peaks, very low permeability, not recommended forrepetitive injections from the same vial. Includes aluminum capsand star springs. Note: Due to the patent which PerkinElmer holds on the closures system of the Headspace vials, the...
The MID IR SOURCER ELEMENT by PerkinElmer is a critical component for enhancing the performance of FT-IR spectroscopy systems. It facilitates accurate mid-infrared light emission, crucial for detailed molecular analysis. This element is engineered to provide consistent output, supporting precise and...
This is a multi-element standard containing the following elements: Ag, Al, B, Ba, Bi, Ca, Cd, Cr, Cu, Fe, In, Li, K, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Si, Sn, Ti, V, Zn. Matrix: Hydrocarbon oil.
The Tip Kit includes a clear sapphire sample tip and a red ruby argon tip. The tips are constructed of PEEK with the gem inserts noted for maximum corrosion resistance.
These kits are required for all the PerkinElmer FT-IR Spectrometers to keep the optical path free from moisture. It is recommended that the desiccant is replaced every six months. Follow the instructions in the appropriate instrument manual to install the desiccant.
PerkinElmer vials are manufactured to specific tolerances that are guaranteed to fit and perform with PerkinElmer and non-PerkinElmer instruments.Our vials are manufactured from Type I Borosilicate Glass, which meets all USP, JP, and EP Pharmacopeia requirements. The glass performs excellent at high...
Concentration: 1,000 µg/mL Matrix: 2% HNO3 Volume: 500 mL Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported at...
PerkinElmer offers a variety of caps and septa to fulfil your application needs. Our screw thread vial caps use the revolutionary Inter-Seal®. Using a process that bonds silicone/ PTFE and other elastomeric compounds directly into thermoplastic closures eliminates liner fallout, while still...
Hydrophobic PTFE syringe filters have broad chemical compatibility and high pH resistance. These are versatile filters for use with aggressive organic solvent-based solutions and are especially ideal for HPLC sample preparation. The pure polypropylene housings are color-coded and available in smooth...
Indicates that SCHOTT type UK 5 is used for cells referred to in the catalog as manufactured from “Special Optical Glass”. This crown glass is made from exceptionally pure raw materials, which gives an improved transmission in the near ultraviolet range. An empty cell will give a transmission of...
This kit includes: O-Ring 20.3 mm I.D., Qty. 2 (09902223) O-Ring 2.57 mm I.D., Qty. 2 (N0791334) Plastic O-Ring Removal Pick, Qty. 1 (09220410)