PerkinElmer Lab Supplies

PerkinElmer Lab Supplies

Products (591)

Compare Tool

Select up to 3 products

  • PTFE Torch Light Shield Disk for NexION 2000/1000

    The light shield protects the torch from discoloration caused by the plasma. The Torch Light Shield Disk is included in the PFA-Platinum HF-Resistant Sample Introduction Kit (N8150033), the Organics Sample Introduction Kit (N8150031), the NexION 2000 Base Configuration's Sample Introduction Kit...

  • Tin (Sn) System 2 Electrodeless Discharge Lamp

    System 2 electrodeless discharge lamp for the detection of elemental Tin (Sn). Note: PinAAcle ™ instruments require the purchase of an EDL driver assembly, part number 03030997, for each of the lamp positions to be used. Electrodeless Discharge Lamps for greater brightness (EDLs) are typically...

  • Cable for Edgeport Box

    Cable to integrate Edgeport communication box (09402019). 10ft The Cable for Edgeport Box by PerkinElmer is a critical component for connecting the Edgeport Box to gas chromatography instruments. This cable is designed to ensure stable and reliable data transmission, essential for accurate...

  • Rhrenium 1 µg/mL Single Element Pure Standard

    Each standard is supplied with a comprehensive Certificate of Analysis that documents its quality and reliability. Each standard: Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported at...

  • Chromium (Cr) Pure Single-Element Standard, 1,000 µg/mL, 2% HNO3

    Concentration: 1,000 µg/mL Matrix: 2% HNO3 Volume: 500 mL Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported at...

  • Vanadium (V) Lumina Hollow Cathode Lamp

    Single Element Lumina hollow cathode lamp (HCL) for the detection of elemental Vanadium (V). Please note that this element requires the use of a nitrous oxide-acetylene flame. Every genuine PerkinElmer lamp is designed for use with and tested on PerkinElmer spectrometers to assure compatibility and...

  • Air Filter for the Fan of the Main Power Supply

    Air filter is for the fan of the main power supply. The Air Filter for the Fan of the Main Power Supply by PerkinElmer ensures optimal airflow, enhancing the performance and lifespan of equipment. This filter effectively captures dust and other airborne particles, preventing them from entering the...

  • Soft Carrying Case

    Soft carrying case for Portable Electronic Leak Detector (N9306089)

  • Black/Black 0.76mm i.d. PVC Peristaltic Pump Tubing

    Inner diameter 0.030 in. (0.76 mm). PerkinElmer offers a wide range of high-quality peristaltic pump tubing for all of your ICP-OES and ICP-MS applications. Remember to replace your tubing frequently and always keep spares on hand.

  • AutoSystem Autosampler Syringe, Plunger Type: Metal Plunger in Needle, Volume: 0.5µL, Outer Diameter: 0.63

    Syringes from PerkinElmer are individually inspected for accuracy and performance. Recommended autosampler syringes are available in 0.5, 5 and 50 µL capacities. For routine analyses, the metal plunger in barrel with PTFE-tipped seal is the standard syringe as shipped with each Clarus ® GC...

  • Cone Removal Tool for NexION 1000/2000/300/350

    This cone removal tool is used with NexION 1000, 2000, 300 S, 300 Q, 300 X, 300 D and 350 ICP-MS series instruments.

  • Alumina Injector, 2.0 i.d (standard with Optima instrument) for Optima 8x00

    Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for...

  • Fixed 2.5 mm I.D. Injector Quartz Torch (Green Mark) for NexION 2000/1000

    This one-piece quartz torch, marked blue, with a PVDF o-ring free holder, has a 2.0 mm injector integrated directly into the torch. It's included in the Base Configuration's Sample Introduction Kit (N8150034).

  • Marathon Filament for GC/MS/MS Systems

    The Marathon Filament is a revolutionary technology developed exclusively by PerkinElmer GC/MS and GC/MS/MS systems, delivering long life even under the most difficult chromatography conditions. It is a direct replacement of the previous rhenium filament - no system changes required. At PerkinElmer,...

  • Concentric PTFE Nebulizer - PFA-ST

    Ultraclean PFA PTFE nebulizer with exchangeable capillaries to provide flow rates from 100-400 uL/min. For use with autosamplers. Requires union N8122355 to connect to autosampler probe.

  • O-Ring for Needle Seal Assembly

    TurboMatrix Headspace and high-sensitivity Headspace Trap samplers provide unparalleled precision and ease of use for numerous GC or GC/MS volatile-analysis applications. The system can manage up to 12 samples simultaneously, ensuring that the next sample is ready for analysis upon completion of the...

  • Iron 1 µg/mL Single Element Pure Standard

    Each standard is supplied with a comprehensive Certificate of Analysis that documents its quality and reliability. Each standard: Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported at...

  • PTFE Digestion Tube 50 ml

    The PerkinElmer PTFE Digestion Tube, with a capacity of 50 ml, is designed for rigorous sample digestion processes. Its PTFE construction ensures resistance to chemical reactions and high temperatures, making it suitable for various analytical methods. The tube's precise design facilitates secure...

  • Magnesium (Mg) Pure Single-Element Standard, 1,000 µg/mL, 2% HNO3

    Concentration: 1,000 µg/mL Matrix: 2% HNO3 Volume: 500 mL Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported at...

  • Solution - NexION Dual Detector

    This kit includes: 1% HNO3 1 x 250 mL NexION Wash Solution, 1 X 500 mL NexION Setup Solution, 1 x 250 mL NexION KED Setup Solution, 1 x 500 mL NexION 300X/D/S Cell Stability Solution, 1 x 100 mL NexION Standard/DRC Mode Detection Limit Blank Solution, 1 x 100 mL NexION Standard/DRC Mode Detection...

  • Blue/Yellow/Blue 1.52 mm i.d. PVC Peristaltic Pump Tubing, 3-stop2

    Peristaltic pump tubing has a wall thickness of 0.84mm unless noted otherwise.

  • SC Autosampler Probe PTFE 1.0mm ID

    A contoured design reduces carryover, while an all PFA wetted sample flow path reduces contamination. SC Autosampler Probe, Carbon fiber support, 1.0mm ID (gray marker), long probe, long capillary, connects to port #5 (¼-28 fitting) high flow.

  • Impact Bead for High Sensitivity Nebulizer with Pt/lr or Tantalum Capillary

    Impact Bead for High Sensitivity Nebulizer with Pt/lr or Tantalum Capillary for PerkinElmer AAnalyst 100/300/700/800, 5100 PC, 5000,3300, 3110, 3100 4100, 2100, 1100(B)and earlier AAs. Included with High Sensitivity GemTip Nebulizer only. Inert plastic body with red adjusting ring

  • Spike Sample (ICP), Matrix per Volume 5% HNO3 per 100mL

    Spike Sample (ICP), Matrix per Volume 5% HNO3 per 100mL, Concentration of Element: 200 µg/mL AI, 50µg/mL Sb, 200µg/mL As, 200µg/mL Ba, 5µg/mL Be, 5µg/mL Cd, 20µg/mL Cr, 50µg/mL Co, 25µg/mL Cu, 100µg/mL Fe, 50µg/mL Pb, 50µg/mL Mn, 50µg/mL Ni, 200µg/mL Se, 5µg/mL Ag, 200µg/mL Tl, 50µg/mL V,...

Compare Tool

Select up to 3 products