Select up to 3 products
Storage Box, Adjustable Compartments, Synthware, Polypropylene, for storage of 14/10 microscale kit components.
Flanged type stopper with a hollow plud and sleeve extension that folds down over the neck of vessel, tubing, etc. The diaphragm can be punctured with a syringe needle, resealing after need is withdrawn.
Craig Recrystallization Tube, Synthware, Complete with glass outer tube and inner plug, Capacity Below Grind: 2mL.
High Vacuum Valve Meteing Plug, PTFE Protected, Synthware, Size: 0-4, 08 and 0-12mm available. The High Vacuum Valve Metering Plugs, from the trusted brand Kemtech America, are designed for precise control and durability in high vacuum applications. These metering plugs are ideal for regulating the...
Trap is placed between the vapor tube and the evaporation flask. This design prevent possible contamination in the event of bumping. With two 4mm drain holes at the base of the inner tube to allow solvent to drain back into the evaporation flask. Has upper outer and lower inner standard taper...
Coiled Condenser, Removable Hose Connections Joints: 24/40 or 29/42, Jacket Length, 200, 300 and 400mm available Hose Connection: 8mm **NOTE THESE PRODUCTS COME IN DIFFERENT SIZES - WHAT IS PICTURED MAY NOT BE THE ITEM SOLD**
SYNTHWARE pear shaped, heavy wall, single neck flasks with a standard taper outer joint. All sizes are hand blown from tubing to ensure uniform wall thickness.
SYNTHWARE general purpose chromatography column with heavy wall design. With reinforced beaded top. Supplied with a PTFE stopcock. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Note: since the chromatography column is used with positive air pressure,...
Designed for microscale application. With one female joint and four drip-tip male joints. The Synthware Distillation Cow Receiver is designed for the simultaneous collection of multiple distillates, optimizing distillation efficiency. This receiver is crafted from high-quality glass, providing...
Heat Transfer Block, Round bottom flasks, Synthware, Holds 5, 10 and 25mL round bottom flasks.
West Condenser Joints: 14/20, 19/22, and 24/40 available Jacket Length: 110, 190, 200, and 300mm available Narrow annular space for fast collant speed thus high cooling efficiency.
Allows for flexible tubing to be connected to apparatus for introduction of vacuum or pressure. Hose connection is at a 90 degree angle to the standard taper inner joint.
Addition Funnel, Pressure Equalizing, High Vacuum Valve, Synthware, Capacity: 25-250mL available, Joints: 14/20, 19/22 or 24/40 available, Valve Size: 0-4mm, Valve has extended tip for semi-needle valve adjustment.
With a joint at 15° angle. Supplied completely with Nylon® cap and hose connections.
Drying samples for elemental analysis. Sample is placed in a vial which is placed into drying chamber. Under vacuum and gentle heat created by refluxing in outer jacket of low boiling point solvents.
SYNTHWARE short chrmoatography column with a lower standard taper 24/40 inner joint with a sealed in drip tip and a hose connection. Designed to perform seperations using a vacuum source. All sizes have a fritted disc to support column packing.
Joint Sleeve, PTFE, Ribbed with gripping ring, Synthware, Sizes available to fit various joint sizes.
Gas washing bottle with an extra large diameter (60mm) fritted disc sealed into the bottom of the bottle to enable increased gas throughput and uniform gas distribution. Available with coarse fritted disc. The 24/40 standard taper top outer joint accepts a A292440 gas inlet adapter which is supplied...
Using 47mm membranes for filtering corrosive solutions, particulate removal from HPLC solvents, and filtration analysis with solid phase extraction disks. Support base has removable 47mm stainless steel support screen for use with viscous or proteinaceous solutions. Complete assembly includes a...
SYNTHWARE modified Schlenk flask with a standard taper outer joint and 2mm bore glass stopcock in side arm. The Kjeldahl shape permits easy transfer of liquids and solids. The lower portion of the flasks fits standard heating mantles to facilitate heating and stirring.
One-piece design for easy set-up. For the best result, use D272440 distillation receiver. To be used with 25mm immersion thermometer.
Vacuum Trap with #15 O-ring joint Features 0-12mm high vaccum valve as the shut off. Connection is made via a 57mm O-ring flat flange. Length below flange is 300mm. Steel Clamps sold seperately.
With 4mm double oblique, high vacuum solid glass stopcocks precision ground with corresponding numbers on barrel and plug. Solid glass stopcocks have constant pressure retention devices. Distance between stopcocks is 75mm center to center.
Adapter has a Nylon compression cap and a Viton o-ring to form a vacuum tight seal. Cap accommodates 5.0 - 7.5mm O.D. thermometer or gas inlet tube. The 8mm hose connection can be used for N2/Ar introduction or vacuum. Supplied with one Nylon cap and one Viton o-ring.