Agilent Technologies Lab Supplies

Agilent Technologies Lab Supplies

Products (15073)

Compare Tool

Select up to 3 products

  • < Previous
  • > Next
  • Captiva Filter Plate

    Agilent Technologies

    Captiva filtration plates and cartridges completely remove precipitated proteins and strongly protect against HPLC column clogging. Captiva 96-well filter plates, available in 0.2 and 0.45 µm pore sizes, are ideal for preparing precipitated protein samples for LC/MS. Captiva 10 and 20 µm glass fiber...

  • Plain PL-Latex

    Agilent Technologies

    Agilent offers a range of polystyrene-based uniform latex particles for research and for rapid, user-friendly, and cost-effective diagnostic tests. Our expertise in the manufacturing and characterization of polymers means we can offer a custom manufacturing service, all with a high level of quality...

  • Wash seal PE 1290 Infinity LC, 1/pk

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • WAX Gas Chromatography Column

    Agilent Technologies

    HP-INNOWax is a polyethylene glycol (PEG) stationary phase that features high polarity and high upper temperature limits. It is a close equivalent to USP phase G16 and is targeted at food, flavor, and fragrance applications. Agilent J&W HP-INNOWax GC columns utilize the same innovative inert...

  • PL-SAX PL-SAX Column for Biomolecules

    PL-SAX for Biomolecules is ideal for the anion-exchange HPLC separations of synthetic oligonucleotides. The covalently linked strong anion exchange functionality extends the operating pH and temperature range, essential for oligonucleotide purification and analysis. With PL-SAX for Biomolecules,...

  • EPA Method 525.2 Kit  acetone KIT

    EPA, Method: 525.2.

  • GC Capillary Column

    Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is only...

  • Sapphire plunger LC-20AD/20ADXR/20AB SHM

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • GC Capillary Column

    Agilent Technologies

    Gas Chromatography (GC) columns are at the heart of the gas chromatograph and responsible for the separation process. GC is one of the most important and critical tools in analytical chemistry, because of its effectiveness, sensitivity and ease-of-use. GC columns contain a stationary phase,...

  • ICP Wavelength Calibration Standard

    ICP wavelength calibration Standard

  • POLYURETHANE,1/16inx1/8inx25ft,CLEARTUB.

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • Heptachlor Epoxide (Isomer B) Standard 100 ug/mL cyclohexane 1X1ML

    Analyte: Heptachlor epoxide - isomer b, CAS Number: 1024-57-3.

  • O-Ring

    Agilent Technologies

    A number of O-rings are used throughout the current Agilent Mark 7 flame atomization system, and the earlier Agilent Mark VI flame atomization system, including on nebulizer components, the spray chamber and the burner. Regular inspection of the O-rings is recommended, especially when completing...

  • GC Capillary Column

    Agilent Technologies

    Gas Chromatography (GC) columns are at the heart of the gas chromatograph and responsible for the separation process. GC is one of the most important and critical tools in analytical chemistry, because of its effectiveness, sensitivity and ease-of-use. GC columns contain a stationary phase,...

  • 2-AB Labeled Glycan Standard

    Agilent Technologies

    Agilent 2-AB (formerly ProZyme) labeled N-glycan standards and libraries are commonly used as qualitative standards for LC/FLD and LC/MS. 2-AB standards come pre-labeled with 2-AB, ready to reconstitute and inject. The sialic acid linkage of the sialylated glycans within the 2-AB library are a(2, 6)...

  • ZORBAX Extend 300 C18, 2.1 x 50 mm, 3.5 um

    ZORBAX Extend 300 C18, 2.1 x 50 mm, 3.5 µm HPLC column. ZORBAX 300Extend-C18 columns incorporate a unique patented bidentate silane, combined with a double-endcapping process that protects the silica from dissolution at high pH. Agilent Technologies products are intended for sale/shipment...

  • Polymethylmethacrylate (PMMA) Individual Standard

    Polymethylmethacrylate (PMMA) standards are extremely versatile as they can be used for organic GPC with a wide range of medium polarity eluents, such as tetrahydrofuran, toluene, methyl ethyl ketone, and ethyl acetate. They also work well with more polar organic eluents, for example...

  • Gas Chromatography Capillary Column

    Agilent J&W HP-1ms is a high-quality, 100% dimethylpolysiloxane, nonpolar phase with identical selectivity to HP-1. An excellent general-purpose column with low-bleed characteristics and improved signal-to-noise, it delivers outstanding performance and sensitivity, resulting in greater mass spectral...

  • Metal Gas Chromatography Column

    Agilent J&W CP-SimDist UltiMetal performs extended analysis to C120, and is guaranteed to a Tmax of 450 °C, due to the virtually unbreakable inert UltiMetal tubing. The internal diameter of UltiMetal tubing is the same as for fused silica 0.53 mm id (Megabore) columns, providing trouble-free...

  • Spray Chamber for UHMI, 7900 ICP-MS 1/pk

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • Captiva Syringe Filter

    Agilent Technologies

    The Agilent 15 mm premium captiva syringe filter is made of polypropylene that offers long lasting durability. It is tested and certified to be free of UV-absorbing substances. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.

  • InfinityLab Poroshell 120 UHPLC Guard Column

    InfinityLab Poroshell 120 HILIC columns for hydrophilic interaction liquid chromatography (HILIC) are designed for the retention and high-resolution separation of small polar analytes. The superficially porous character of the particles decreases equilibration times to improve throughput for both...

  • Sebuthylazine Standard 1000 ug/mL acetonitrile 1X1ML

    Analyte: Sebuthylazine, CAS Number: 7286-69-3.

  • Bond Elut Solid Phase Extraction Cartridge

    Bond Elut Carbon cartridges are packed with ultrapure graphitized carbon particles that have been optimized for the absorption of pigments in food, fruits, vegetables, and small organic residues in wastewater. The powerful retention mechanisms of these products are appropriate for a broad range of...

  • < Previous
  • > Next

Compare Tool

Select up to 3 products