Cloud point and pour point are indicators of the lowest temperature of utility for petroleum products. The sample is periodically examined while it is being cooled in the cloud and pour point apparatus. The highest temperature at which haziness is observed (cloud point) or the lowest temperature at…
-
Portable Heated Centrifuge
KoehlerThomas No. 1209P98 - Portable Heated Centrifuge For the determination of water and sediment of crude oil by centrifuge method during field custody transfers. This test method is considered the most practical method for field determination of sediment and water in conformance with D96. Thomas…
-
Test Method For flash point determinations of fuels, lubricating oils, liquids containing suspended solids and liquids that tend to form a surface film during testing. Pensky-Martens Closed Cup Flash Tester Conforms to ASTM D93 and related specifications Choice of electric or…
-
-
The sample is evaporated and condensed under controlled conditions, and observations are made of the temperatures at which various percentages are recovered and/or the percentages recovered at specified temperatures. Conforms to ASTM D86, E133, and related ASTM and international standards …
-
Carbon Residue Apparatus
KoehlerThermostatically controlled coking furnace for five samples Conforms to ASTM D 524 and related specifications Microprocessor temperature control with digital display and over-temperature cut-off Reaches standard test temperature of 550°C rapidly and controls with…
-
Auto Heated Centrifuge
KoehlerLong tube rotor assembly, 115 and 220 Volt fully automated bench top centrifuge with integrated heating system which accommodates a capacity of 4 tubes Short tube rotor assembly, 115 and 220 Volt fully automated bench top centrifuge with integrated heating system which accommodates a capacity…
-
U-Tube Aniline Point Apparatus
KoehlerDeveloped by Standard Inspection Laboratories Suitable for samples having 6.5 or lighter ASTM D 1500 color. Accessory Powertol Heater provides variable stepless control of heating rate and 6 V tap for lamp.
-
Accessory for the K19500 Penetrometer ( 7151K11 ). Cone penetration of lubricating greases Test Method Standards: ASTM D217; IP 50; ISO 2137; DIN 51804; FTM 791-311, FTM 791-313
-
Metal Strip Corrosion Test Bombs
KoehlerCopper Strip Corrosion Test Bomb Conforms to range of standards Precision-machined stainless steel bomb inserts in copper corrosion bath for testing aviation fuels and natural gasoline. Bomb withstands test pressure of 100 psi (689 kPa) per specifications. Threaded cap with O-ring…
-
Polarimeter Tubes
KoehlerInversion Polarimeter Tubes Glass, approximately 9 mm i.d., with threaded, metal ferrule litharge-sealed to tube at each end Metal, cover-glass retaining caps, threaded to attach to ferrule Cap diameters closely controlled to ensure concentricity of tube with optical path in polarimeter …
-
Removes all traces of oil Air pressure drives solvent No electrical contact needed Unit is designed to wash the inside of glass kinematic viscometer tubes with a jet of solvent. At the touch of a button, the solvent stream is cut off and an air jet is directed into the tubes for…
-
Assess the relative degree of corrosivity of petroleum products Test baths can be used to test automative gasoline, natural gasoline, solvents, kerosene, diesel fuel, distillate fuel oil, lubricating oil and other products. A polished copper strip is immersed in 30 mL of sample at elevated…
-
-
-
Precisely machined brass and stainless steel tubes meeting ASTM requirements. Tubes mount vertically in Saybolt Viscometer Baths and accommodate stainless steel orifices interchangeably. Supplied with mounting hardware.
-
16" Oil Thief Sampler
Koehler16" 33 oz capactiy Polycarbonate Oil Thief Sampler with 3 Petcocks at 2", 4" and 8"
-
Saybolt Viscometer Bath
KoehlerAutomatic timing option for simplified, accurate measurement of efflux times Microprocessor controls temperature between ambient and 240°C (464°F) Four-tube capacity Dual digital displays show setpoint and actual temperature °C/°F selectable Conforms to ASTM…
-
Thermohydrometers
KoehlerStandard temperature 60°F, subdivisions 0.1° API, length 380mm, thermometer scale °F 0-150 (designation L), 30 to 180 (designation M), 60 to 220 (designation H)
-
Existent Gum Steam Generator
KoehlerElectrically heated boiler provides instantaneous and reserve steam capacity for steam-jet evaporation tests. Easy to install and operate; electrical heating eliminates the need for on-site fuel combustion. Requires only a water feed source and electrical hook-up. Ruggedly constructed, with long…
-
Reverse-flow viscometer for opaque liquids having kinematic viscosities of up to 300,000cSt. Requires a sample of 12-25mL. Use with K23330 rectangular metal holders or K23387 round plastic holders. Length: 275mm
-
-
-
Indicates petroleum products low temperature utility limit Conforms to ASTM D97, D2500 and related specifications Compact four-place portable chamber Mechanically refrigerated models with factory preset cold baths Immerses four copper test jackets in suitable freezing mixtures at the…
-
Rotor Assembly for Long Tubes
KoehlerThomas Nos. 1209Q14 – 1209Q16 Tube is 8" Marked in mL and can be used with our Oil Test Centrifuge with Long Cone Rotor in conformance with D91, D96, D893, D1796, D4007 Thomas No. 1209Q17 Tube is 8" Marked in mL and can be used with our Oil Test Centrifuge with Long Cone…
-
-
Penetrometer Bath
KoehlerDigital temperature control with low-liquid and overtemperature safety cutoff Conforms to ASTM and related specifications Conditions petroleum samples and others requiring close temperature control prior to or during testing For use with manual and microprocessor penetrometer models Has…
-