  • Cannon Fenske Routine, CFRU (Uncalibrated) & CFRC (Calibrated) Viscometers For measurement of kinematic viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and…

  • Cannon Instrument

    For Thomas®-Stormer® Viscometers Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate viscosity in centipoise and Krebs unit values at 25°C are given in table below. Actual value are furnished with each standard. Supplied in a one pint bottle.

  • Four Bulb Shear Dilution- Five-fold Dilution Type, Cannon CUSDC-11 Series For measurement of intrinsic viscosities extrapolated to zero shear rate Provides five-fold range of shear rates Design gives extra mechanical strength Negligible kinetic energy correction Precision:…

  • Calibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two…

  • CANNON Instrument Company has released a line of viscosity check oils specifically designed for verification of SAE target viscosities per ASTM D 445, D 5293, and D 4684. The CVCO (Certified Viscosity Check Oil) series includes formulated commercial engine oils with certified values for kinematic…

  • Calibrated Viscometers For measurement of kinematic viscosity of small samples of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 requirements Precision: ±0.2% Specifications conform with ASTM Standard D 446. Minimum sample…

  • Cannon Instrument

    Programs are supplied on a 3.5” disk. The programs are designed to be user-friendly (they are accessed through a convenient menu system) and are provided with a detailed operator’s manual. The calculations performed include the following: Blending of oils- the W.A. Wright…

  • Cannon Instrument

    N100 Viscosity Standard 1 L

  • Cannon Instrument

    HT22 Viscosity Standard

  • Designed specifically for measuring viscosity at low temperatures using glass capillary viscometers Conforms to ASTM D 445 for low temperature viscometry Peltier cell for thermoelectric cooling Fan-cooled, high-density heat sinks Holds two glass capillary viscometers A…

  • CANNON Low Temperature Viscosity Standards verify viscometer performance at sub-zero temperatures. These standards are applicable to SAE Specification J300 as well as a variety of ASTM Methods including: ASTM D2983, Low-Temperature Viscosity of Lubricants Measured by Brookfi eld…

  • Cannon Instrument

    With three or four manual valves for applying vacuum or pressure to capillary-type viscometers Designed for use with 9726T20 through 9726T67 Vacuum Regulators and Cannon-Manning, Asphalt Institute or Modified Koppers vacuum viscometers (see Thomas number 9724H50) Integral brackets permit…

  • Wide temperature range 20°C to 150°C Easy temperature setting Insulated for precise solid-state temperature control Multiple safety features Ideal for temperature control of other instruments which must be viewed while immersed in a constant temperature bath. The top…

  • CT-500 Temperature range 20° to 100°C Easy temperature setting Precise solid state temperature control within 0.01°C Multiple safety features The top cover contains seven round holes 51 mm (2") in diameter. Each unit maintains accurate temperature control of 0.01°C within the range of…

  • Ideal for kinematic viscosity determinations between 10°C and 30°C Built-in thermoelectric cooling provides “rock-solid” temperature control at ambient and below Meets ASTM D 445 precision specifications from 10°C to 100°C The Cannon CT-600 has many of the engineering and control features of…

  • Calibrated viscometers For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F and asphalt…

  • The Dostmann P795 dual channel digital thermometer is a precision hand held device for accurate temperature measurement. Dual channel technology allows simultaneous display of two readings or a differential result to meet the needs of automated viscosity applications, such as side-by-side kinematic…

  • For use with Cannon High Temperature/ High Shear Viscometers for measurements at 150°C and 10 -6 s -1 shear rate Based on NIST value of 1.0016 centipoise for water at 20°C; traceable to the NIST In accordance with ASTM Standard D 4624 9727U92 and U94 are non-Newtonian…

  • Quick and reliable automation Direct kinematic viscosity, no need to correlate data Modified cross-arm style tube, works with both transparent and opaque oils Reliable, only 2 moving parts Easy-to-use graphical touch screen Small sample volume: <0.5 mL Rapid automated analysis: <3…

  • For ink and paint viscometers For use with Zahn, Shell and Ford viscometer cups. Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate kinematic viscosity and drain times for the various cups at 25°C are given in table. Actual values are furnished…

  • Similar to Cannon-Manning Vacuum (CMV, 9724-H50) series, but with graduated capillary instead of two timing bulbs. Provided with certificate of calibration and instruction sheet. Viscosity range, poise: 2400 - 52000 Approx. constant poise/second at 300mm Hg Bulb B: 128 Approx.…

  • Cannon Instrument

    Thermoelectrically cool baths up to 15°C below ambient 1/10 the size of standard refrigeration units Power consumption of only 250 watts Simple to operate with low maintenance Cooling fans are the only moving parts CBC bath coolers consist of a thermoelectric cooling unit and a separate…

  • The Cannon Instrument probe is suitable for use with Dostmann dual channel digital thermometers for various viscometer models. You can choose ideal replacement part or accessory which ensures smooth functioning of thermometer units.

  • Cannon ZCAC Series For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445 specifications; also conform to ASTM Standard D 446 Precision: ±0.3% Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F (60°C) and…

  • Microprocessor controlled temperature regulation from 10 to 150°C Conforms to ASTM D 445 Built-in platinum resistance thermometer On-screen temperature monitoring RS 232 and RS 485 communication ports A keypad permits temperature selection to two decimal…

  • Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of…

  • Cannon Instrument

    All Cannon viscometer holders are designed to fit holes 51 mm (2 in.) in diameter. Rubber holders are made of neoprene rubber.  Plastic holders hold the viscometer firmly with a spring clip.  Metal holders are constructed of chrome-plated machined brass.  A handle permits…

  • Cannon Instrument

    Includes permanently attached round metal holder, for hole 51 mm (2 in) in diameter.

  • quick-ship

    Cannon Instrument

    For calibration of rotational viscometers Viscosity certified at 20, 23, 24, 25, 26 and 27°C Calibrated to a precision of ±0.2% NIST traceable Standards are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa-s (centipoise) for…

  • Cannon Instrument

    The Cannon Instrument large vial is an ideal accessory to have in any chemical laboratories, research facilities, manufacturing industries and pharmaceutical factories.

  • Based on NIST value of 1.0016 centipoise for water at 20C; conforms to ASTM Standards D 445, D 88 and D 2161; traceable to NIST Approximate viscosities at varying temperatures in centistokes and centipoises are given in Table 1; each standard is furnished with actual viscosity and density…

  • Uncalibrated and Calibrated Viscometers Suspended level viscometer for measurement of kinematic viscosity of transparent Newtonian liquids Also used for evaluating jet fuels and hydraulic fluids Meets ASTM D 445 and D 446, as well as ISO 3104 and 3105 requirements Suitable for use at…