CDS Empore™
-
6093 SDB-XC StageTips
CDS Empore™CDS Empore 6093 StageTips SDB-XC (styrenedivinyl benzene) polymer sorbent Solid phase extraction micropipette tips 2-layers for increased capacity. Combine good retention capacity with high recoveries. Recommended for desalting of large peptides and proteins and peptide fractionation at…
-
6094 SDB-RPS StageTips
CDS Empore™CDS Empore 6094 StageTips SDB-RPS (styrenedivinyl benzene reverse phase sulfonate) polymer sorbent Solid phase extraction micropipette tips 2-layers for increased capacity. Combine good retention capacity with high recoveries. Recommended for desalting of large peptides and proteins and…
-
CDS Empore™ 3291: Radium Rad Disk
CDS Empore™Molecular recognition technology-Crown Ether bonded Silica particles (12um) for Radium isotopes 226 and 228. Capture the selected analyte and then also as the counting medium (liquid scintillation or counting). Reduces turnaround time and lowers operating costs.
-
6092 C8 StageTips
CDS Empore™CDS Empore 6092 StageTips C8 bonded silica Solid phase extraction micropipette tips 2-layers for increased capacity. Combine good retention capacity with high recoveries. Recommended for desalting of large peptides and proteins and peptide fractionation at acidic neutral and basic pH conditions.
-
3293 Cesium RAD Disk
CDS Empore™CDS Empore 3293 Cesium 47mm RAD Extraction Disk. Used for the extraction of Cs-137 from environmental water samples. Provide an efficient alternative to convential radiochemical sample preparation methods that use wet chemistry or packed columns. Molecular recognition technology. Reduces turnaround…
-
CDS Empore™ 6065: 96-Well Filter Plates
CDS Empore™Good to remove visible particulates (>10um) from samples in the 96-well plate format (>98% removal), while maintaining excellent flow characteristics.
-
Combine good retention capacity with high recoveries. Reverse phase with cation exchange. Recommended for moderately polar to non-polar analyte extractions.
-
CDS Empore™ 2370: Oil & Grease Disk
CDS Empore™One-Piece (C18 bonded silica, bead and depth filter) design eliminates additional prefilter and filter aids. Provide up to 90% solvent reduction, excellent processing speed (fast flow rates), and contamination-free extractions with accurate and reproducible results. EPA Method 1664.
-
pH range 1-14. Reversed phase, pi-pi and cation exchange interactions. Analytes: reversed phase, aromatic, and positively charged species. Drugs/Pesticides and metabolites.
-
CDS Empore™ 6036: 96 Deep Well Filter Plates
CDS Empore™Good to remove visible particulates (>10um) from samples in the 96-well plate format (>98% removal), while maintaining excellent flow characteristics.
-
EDC Chelating
CDS Empore™Combine good retention capacity with high recoveries. Recommended for extractions multivalent metal ions and other divalent cations.
-
The carbon surface includes positive and negative charges. Extraction of highly polar compounds, such as N-nitrosodimethylamine,oxamyl and methamidophos, and volatile compounds such as trihalomethanes.
-
Combine good retention capacity with high recoveries. Recommended for extractions of positively charged ions
-
CDS Empore™ 3292: Technetium Rad Disk
CDS Empore™Molecular recognition technology-Crown Ether bonded Silica particles (12um) for Technetium Isotop 99. Capture the selected analyte and then also as the counting medium (liquid scintillation or counting). Reduces turnaround time and lowers operating costs.
-
Combine good retention capacity with high recoveries. Recommended for extractions of negatively charged ions.
-
CDS Empore™ 2252: Anion Exchange, 12um SPE Disk
CDS Empore™pH range 1-14. Polymer-based Strong Anion exchange for extacting negative charged ions. EPA Methods 548.1, 552.1, Carboxylic acid metabolites, Removal of humic and fulvic acid interferences from water samples, etc.
-
6097 C18/SCX StageTips
CDS Empore™CDS Empore 6097 StageTips C18 bonded silica and Cation exchange (SCX) Solid phase extraction micropipette tips. Combine good retention capacity with high recoveries. Recommended for desalting of large peptides and proteins and peptide fractionation at acidic neutral and basic pH conditions.
-
6095 Anion StageTips
CDS Empore™CDS Empore 6095 StageTips anion exchange (SAX) polymer sorbent Solid phase extraction micropipette tips 2-layers for increased capacity. Combine good retention capacity with high recoveries. Recommended for peptide fractionation at acidic neutral and basic pH conditions.
-
Use as a filtration aid when extracting samples with a high particulate content using Empore disks. Approximately 40grams to cover a 90 mm disk 1cm deep. Approximately 15grams to cover a 47mm disk 1cm deep.
-
Combine good retention capacity with high recoveries. End-capped to minimize polar interactions. Recommended for non-polar analyte extractions.
-
Combine good retention capacity with high recoveries. Recommended for moderately polar to non-polar analyte extractions.
-
pH range 1-14. Recommended for moderate non-polar analytes or aromatic analytes extractions. EPA 515.2 or other EPA methods calling for an SDB sorbent.
-
CDS Empore™ 2270: Oil & Grease Disk
CDS Empore™One-Piece (C18 bonded silica, bead and depth filter) design eliminates additional prefilter and filter aids. Provide up to 90% solvent reduction, excellent processing speed (fast flow rates), and contamination-free extractions with accurate and reproducible results. EPA Method 1664.
-
pH range 1-14. Extacting postive charged ions. Extraction and recovery of primary, secondary and some tertiary amines as well as most metal cations from aqueous solutions. Not for quarternary amines.
-
6091 C18 StageTips
CDS Empore™CDS Empore 6091 StageTips C18 bonded silica Solid phase extraction micropipette tips 2-layers for increased capacity. Combine good retention capacity with high recoveries. Recommended for desalting of large peptides and proteins and peptide fractionation at acidic neutral and basic pH conditions.
-
6098 C18/SCX/C18 StageTips
CDS Empore™CDS Empore 6098 StageTips with C18/SCX/C18 layers C18 and cation exchange (SCX) Solid phase extraction micropipette tips. Combine good retention capacity with high recoveries. Recommended for desalting of large peptides and proteins and peptide fractionation at acidic neutral and basic pH conditions.
-
The carbon surface includes positive and negative charges. Extraction of highly polar compounds, such as N-nitrosodimethylamine,oxamyl and methamidophos, and volatile compounds such as trihalomethanes.
-
Combine good retention capacity with high recoveries. Recommended for strong to modest non-polar analyte extractions.
-
6096 Cation StageTips
CDS Empore™CDS Empore 6096 StageTips cation exchange (SCX) polymer sorbent Solid phase extraction micropipette tips 2-layers for increased capacity. Combine good retention capacity with high recoveries. Recommended for peptide fractionation at acidic neutral and basic pH conditions.
-
Combine good retention capacity with high recoveries. End-capped to minimize polar interactions. Recommended for strong non-polar analyte extractions. EPA Methods 506,508.1,525.2, 550.1,608,1613B, etc.
-
CDS Empore™ 660: 96-Well Sealing Tape Pad
CDS Empore™Good to remove visible particulates (>10um) from samples in the 96-well plate format (>98% removal), while maintaining excellent flow characteristics.
-
pH range 1-14. Recommended for moderate non-polar analytes or aromatic analytes extractions. EPA 515.2 or other EPA methods calling for an SDB sorbent.