Glass Viscometers
-
Cannon-Fenske Series Viscometers
Cannon InstrumentCannon Fenske Routine, CFRU (Uncalibrated) & CFRC (Calibrated) Viscometers For measurement of kinematic viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and…
-
BS/IP/SL Suspended Level Viscometer
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105 Precision: ±0.2% Minimum sample volume: 11 mL. Requires liquid bath depth of 250 mm (10”).…
-
BS/U Tube Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires…
-
Viscometer, Modified Ubbelohde
Ace GlassUsed in ASTM Method D 1601. A test for Dilute Solution Viscosity of Ethylene Polymers at 130 degree C. It is applicable to a reasonably wide spectrum of ethylene polymers having densities from 0.913 to 0.970g/cc. Available in capillary sizes .6, .7, and .8mm.
-
Modified Koppers Vacuum, Cannon Mkvc Series Viscometers
Cannon InstrumentCalibrated viscometers For measuring viscosity of asphalt at 60°C (140°F) Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 42 to 200,000 poises. Two-piece design, with sample reservoir and calibrated capillary Vacuum of 300 mm Hg must be applied to top of capillary…
-
Cannon Four Bulb Shear Dilution Viscometers
Cannon InstrumentFour Bulb Shear Dilution- Five-fold Dilution Type, Cannon CUSDC-11 Series For measurement of intrinsic viscosities extrapolated to zero shear rate Provides five-fold range of shear rates Design gives extra mechanical strength Negligible kinetic energy correction Precision:…
-
BS/IP/RF U-Tube Reversed Flow Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes…
-
Zeitfuchs Cross-Arm Calibrated Viscometers
Cannon InstrumentCannon ZCAC Series For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445 specifications; also conform to ASTM Standard D 446 Precision: ±0.3% Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F (60°C) and…
-
Semi-Micro, Cannon CUSMC Series Viscometer
Cannon InstrumentCalibrated For measurement of kinematic viscosity of small samples of transparent Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Viscometer constant is same at all temperatures Initial sample can be diluted to as much as 20 mL for intrinsic…
-
BS/U/M Miniature U-Tube
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of…
-
Cannon-Ubbelohde UBU And UBC Series
Cannon InstrumentUncalibrated and Calibrated Viscometers Measure kinematic viscosity of transparent Newtonian liquids by suspended level principle Meets ASTM D 445 and D 446 and ISO 3104 and 3105 requirements. Precision: ±0.2% Similar to Cannon-Ubbelohde but less rugged in design.…
-
Cannon-Ubbelohde, CUU And CUC Series Viscometers
Cannon InstrumentUncalibrated and Calibrated Viscometers Suspended level viscometer for measurement of kinematic viscosity of transparent Newtonian liquids Also used for evaluating jet fuels and hydraulic fluids Meets ASTM D 445 and D 446, as well as ISO 3104 and 3105 requirements Suitable for use at…
-
Asphalt Institute Vacuum, Cannon Aivc Series Viscometers
Cannon InstrumentCalibrated viscometers For measuring viscosity of highly viscous materials such as asphalt cement at 60°C (140°F) Meets ASTM D 2171 Applicable to materials with viscosity range of 42 to 5,800,000 poises With graduated capillary to extend viscosity range of viscometer Minimum sample size: 3…
-
Borosilicate Glass Ostwald Oil Viscometer
labForce® (powered by Thomas Scientific)Made with borosilicate glass Without stopcock Time of outflow for water at room temperature: 60 to 100 seconds Minimum sample: 5 mL
-
Cannon-Manning Semi-Micro, Cannon CMSMC Series Viscometers
Cannon InstrumentCalibrated Viscometers For measurement of kinematic viscosity of small samples of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 requirements Precision: ±0.2% Specifications conform with ASTM Standard D 446. Minimum sample…
-
Calibrated viscometers For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F and asphalt…
-
Cannon-Manning Vacuum, Cannon CMVC Series Viscometers
Cannon InstrumentCalibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two…
-
BS/IP/SL(S) Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume:10 mL. Requires liquid bath depth of 230 mm (9”). Includes certificate of…
-
BS/IP/MSL Miniature Suspended Level Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision:±0.2%. Minimum sample volume:4 mL. Requires liquid bath of 305 mm (12”). Includes certificate of…