  • CANNON CL Standards provide certified dynamic viscosity data (in cP or mPa·s) at temperatures from –5°C to –35°C. These standards are used to calibrate the CANNON Cold-Cranking Simulator (CCS) oil testing (see ASTM D 5293 and SAE Specification J300).

  • For use with Cannon High Temperature/ High Shear Viscometers for measurements at 150°C and 10 -6 s -1 shear rate Based on NIST value of 1.0016 centipoise for water at 20°C; traceable to the NIST In accordance with ASTM Standard D 4624 9727U92 and U94 are non-Newtonian…

  • Bond Elut Sodium Sulfate Drying Cartridges simplify drying processes with pre-packed devices. Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent…

  • Agilent Technologies

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • Agilent Technologies

    Bond Elut C8 is very similar in property to C18, but is not as retentive for non-polar compounds due to its shorter hydrocarbon chain and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly-retained for effective elution. The potential for polar…

  • Eichrom

    Eichrom’s DGA Resins are extraction chromatographic materials in which the extractant system is either N,N,N’,N’-tetra-n-octyldiglycolamide (DGA Resin, Normal) or N,N,N’,N’-tetrakis-2-éthylhexyldiglycolamide (DGA Resin, Branched). The bed density of both DGA Resins is approximately 0.38 g/mL, with…

  • MilliporeSigma

    Analytical Standard for gas chromotagaphy. Synonym: 2-Hydroxybenzoic acid methyl ester, Methyl 2-hydroxybenzoate, Oil of wintergreen, Wintergreen oil Linear Formula: 2-(HO)C6H4CO2CH3 Molecular Weight: 152.15

  • Eichrom

    One of the more versatile of Eichrom's analytical products is TEVA Resin. It has been applied on a routine basis to the analysis of technetium, the measurement of the tetravalent actinides, and the separation of americium from lanthanides. It is used alone or can be readily combined with other…

  • Cannon Instrument

    For Thomas®-Stormer® Viscometers Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate viscosity in centipoise and Krebs unit values at 25°C are given in table below. Actual value are furnished with each standard. Supplied in a one pint bottle.

  • Cannon Instrument

    HT22 Viscosity Standard

  • Agilent Technologies

    The Agilent Technologies tee on wall mounted plate is used for easy assembly purposes. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.

  • Precisely machined brass and stainless steel tubes meeting ASTM requirements. Tubes mount vertically in Saybolt Viscometer Baths and accommodate stainless steel orifices interchangeably. Supplied with mounting hardware.

  • Agilent Technologies

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • This 24 hole vacuum box has a high density polyethylene (HDPE) top for acid compatibility and a clear plastic bottom for visibility of collection tubes. Overall dimensions are 57 cm (long) x 14.5 cm (deep) x 18 cm (high.) The box comes complete with a screw in vacuum gauge, a rack insert which…

  • For ink and paint viscometers For use with Zahn, Shell and Ford viscometer cups. Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate kinematic viscosity and drain times for the various cups at 25°C are given in table. Actual values are furnished…

  • Agilent Technologies

    Compare your column’s performance to the test chromatogram shipped with your J and W column from Agilent. The column test standard contains components that test the column for resolution characteristics, efficiency, and inertness. The test mixes are supplied at a concentration of 250…

  • Bond Elut NEXUS is an ultraclean polymeric sorbent, which has bimodal porosity and a high surface area. NEXUS offers a nonpolar retention mechanism with no preconditioning required. The large particle size makes NEXUS ideal for extractions from highly viscous samples, such as horse urine. This…

  • Agilent Technologies

    Bond Elut NEXUS is an ultra-clean, large particle size polymeric SPE ideal for highly viscous samples, available in non-polar or weak cation exchange. Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent…

  • GPC-SEC Calibration Standards (2714X77 to X79) Three different polystyrene standard kits are available for organic GPC column calibration. Each kit contains individual monodisperse polymers that cover low, medium and high molecular weight ranges. Each standard lot is characterized using low-angle…