Thin Layer Chromatography (TLC) Plates
Silica TLC plates are among the most common, featuring a layer of high-quality silica gel that provides excellent separation of components. This silica gel for TLC plates is finely prepared to ensure consistent and reliable results. HPTLC plates (High-Performance Thin Layer Chromatography plates) take this a step further, offering higher resolution and faster analysis times.
These plates are available in various sizes and formats to suit different applications, from small-scale tests to larger analytical needs. Options include standard and UV-activated plates, which are compatible with UV lamps for TLC plates and help visualize compounds that are otherwise invisible to the naked eye. Whether you are conducting routine checks or detailed analysis, TLC plates provide a versatile and reliable solution.
-
Silica Gel HL UNIPLATES
Miles Scientific (Analtech)These are the most rugged silica gel plates available. They not only ease handling and sample application, but also permit the use of up to 80% water in the developing solvent without loss of adherence of the adsorbent layer to the glass plate. Organic binder plates are recommended for all TLC…
-
TLC Developing Tank
DWK Life Sciences (Kimble)Constructed of sturdy molded glass bricks Withstands regular use for many years The tank’s clear sides allow for visual inspection of TLC plates up to 20 x 20 cm size. The top of the tank is ground flat to match the lids and the edges are beveled to remove any sharp edges. The bottoms are…
-
10 cm Developing Tank
General Glass BlowingFlat ground top is beveled on the inner and outer rim Ground flat bottom for stability Holds two 10 x 10 cm plates or four 5 x 10 cm plates Thin-Line units allow for faster and more uniform solvent saturated atmosphere and therefore require less solvent. Inside dimensions: 12 x 6.4…
-
TLC SILICA GEL 60 RP-18 F254S 50 GLASS PLATES 5 X 20 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
TLC Silica gel 60 F254
MilliporeSigmaEMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
-
TLC Silica gel 60 F254
MilliporeSigmaClassic silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to damage the layer.
-
Cellulose MN 300 Native Fibrous Cellulose Layers for TLC
MACHEREY-NAGELFeatures Fiber length (95 %) 2–20 μm, average degree of polymerization 400–500 specific surface acc. to Blaine 15000 cm 2 /g ≤ 20 ppm Fe, 6 ppm Cu, 7 ppm P; dichloromethane extract ≤ 0.25% residue on ignition at 850°C ≤ 1500 ppm available as glass…
-
Baker-flex® Coated TLC Silica Gel Sheets
Avantor - J.T.Baker®Ready-to-use plastic sheets, 50 x 200 mm or 200 x 200 mm, with absorbent coating, which is abrasion-resistant and highly uniform; are easily cut to desired size and allow sample fraction to be cut rather than scraped The silica gel and aluminum oxide sheets have coating approximately 200 microns…
-
TLC Kieselguhr F254
MilliporeSigmaPrecoated Kieselguhr or mixed Silica gel/Kieselguhr plates are only of small importance nowadays. Kieselguhr layers are used like cellulose layers for the TLC separation of polar and moderately polar substances. Polyamide, on the other hand , is used for the separation of flavonoids and other…
-
SIL G Unmodified Standard Silica Layers for TLC
MACHEREY-NAGELSilica 60, specific surface (BET) ~ 500 m 2 /g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 5–17 µm; standard grade Thickness of layer for analytical plates 0.25 mm, for preparative plates 0.5 and 1 mm For 2 mm preparative layers a slightly coarser…
-
Cellulose plates (TLC and HPTLC)
MilliporeSigmaFor analysis of polar substances The organic sorbent cellulose is particularly suitable for the separation of hydrophilic substances by partition chromatography. EMD Millipore cellulose plates include classical TLC grade or HPTLC plates for demanding high-performance separations: TLC…
-
SIL G Unmodified Standard Silica Layers for TLC
MACHEREY-NAGELSilica 60, specific surface (BET) ~ 500 m 2 /g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 5–17 µm; standard grade Thickness of layer for analytical plates 0.25 mm, for preparative plates 0.5 and 1 mm For 2 mm preparative layers a slightly coarser…
-
Nano-SIL NH2 Amino-Modified HPTLC Silica Layers
MACHEREY-NAGELFeatures Base material: nano silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å, specific pore volume 0.75 mL/g particle size 2–10 μm pH stability 2–8 Indicator: acid-resistant product with a pale blue fluorescence for short-wave UV (254…
-
TLC Kieselguhr F254
MilliporeSigmaPrecoated Kieselguhr or mixed Silica gel/Kieselguhr plates are only of small importance nowadays. Kieselguhr layers are used like cellulose layers for the TLC separation of polar and moderately polar substances. Polyamide, on the other hand , is used for the separation of flavonoids and other…
-
Latch-Lid Chromatotank Unit
General Glass BlowingClear glass sides allow unobstructed visual inspection of contents Tank is ground flat to match ground glass lid. Beveled inside and outside to remove any sharp edges. Holds two 20 x 20 cm plates or four 10 x 20 cm plates. Latching device holds the matching ground glass surfaces of the lid…
-
HPTLC Silica gel 60 F254 GLP
MilliporeSigmaThese plates feature individual laser coding for GLP applications. Designed for GLP applications, the tops of each of these plates bear an item, batch, and individual plate number. As a result, lab professionals can easily record and archive every plate they use. Based on proven EMD Millipore…
-
HPTLC silica gel 60
MilliporeSigmaHPTLC plates deliver fast and quantitative analysis of complex samples for manual or automated use. EMD Millipore’s HPTLC silica plates work three times faster than conventional TLC plates – and they’re more sensitive. The particle sizes range in HPTLC is between 4-8µm, which creates a smoother…
-
HPTLC CELLULOSE F 50 GLASS PLATES 20 X 10 CM
MilliporeSigmaCellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid…
-
HPTLC LiChrospher® Silica gel 60 RP-18 WF254s
MilliporeSigmaUnique HPTLC Lichrospher® plates are the first thin layer chromatography plates based on spherical silica particles. They offer the ultimate in thin layer chromatography performance and speed enabling high throughput analysis of complex samples. HS Code: 3822 00 00
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
Nano-SIL C18 Octadecyl-Modified HPTLC Silica Layers
MACHEREY-NAGELFeatures Base material: Nano-silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 2–10 μm, pH stability 2–10 Partial (50%) or complete (100%) octadecyl modification, carbon content 7.5 and 14%, respectively…
-
Unique HPTLC Lichrospher® plates are the first thin layer chromatography plates based on spherical silica particles. They offer the ultimate in thin layer chromatography performance and speed enabling high throughput analysis of complex samples.
-
Labels applied to all 4 sides of the plate. No sequence number duplicates. Exceptional print quality and resolution. Resistant to commonly used laboratory reagents. Resistant to temperature ranges of -80ºC to +52ºC. See Product Details below for bar code label specifications. Microplate…
-
PLC SILICA GEL 60, 0.5 MM 20 GLASS PLATES 20 X 20 CM
MilliporeSigmaPLC plates allow users to separate samples that vary greatly in size – from grams down to milligrams. Available with or without a fluorescence indicator, PLC plates has 0.5 mm thickness. They also use the same proven EMD Millipore silica-binder technology as in analytical TLC plates. To…
-
TLC SILICA GEL 60 RP-8 F254S 25 GLASS PLATES 20 X 20 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Milliporeare well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
Designed for in vitro diagnostic assays. Flat bottom strips are designed to easily break apart and may be used in an "egg-crate" style strip holder that allows each individual well to be positioned back into the plate once broken. High binding surface binds medium (>10kD) and large biomolecules…
-
ADAMANT Unmodified Standard Silica Layers for TLC
MACHEREY-NAGELFeatures Silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 5–17 µm Outstanding hardness and abrasion resistance due to an optimized binder system Increased separation efficiency due to an optimized particle…
-
Rectangular Developing Chambers
General Glass BlowingThe single most useful chamber for the TLC laboratory is a sturdy, molded-glass block of clear glass with flat surface walls, ground lip of uniform flatness, beveled inside and outside to remove any sharp edges. There is a raised ridge midway on the inside ends and bottom of the jar. Inside…
-
TLC Silica Gel 60 F254 Multiformat Pre-scored to 5 x 10 cm
MilliporeSigmaPre-scored glass plates fold into smaller formats with just one easy snap of the fingers. HS Code: 3822 00 00
-
TLC Cellulose
MilliporeSigmaPlates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid derivatives. EMD…
![Site Search powered by SLI Systems](http://assets.resultspage.com/logos/sli_logo_2014.png)