Thin Layer Chromatography (TLC) Plates
Silica TLC plates are among the most common, featuring a layer of high-quality silica gel that provides excellent separation of components. This silica gel for TLC plates is finely prepared to ensure consistent and reliable results. HPTLC plates (High-Performance Thin Layer Chromatography plates) take this a step further, offering higher resolution and faster analysis times.
These plates are available in various sizes and formats to suit different applications, from small-scale tests to larger analytical needs. Options include standard and UV-activated plates, which are compatible with UV lamps for TLC plates and help visualize compounds that are otherwise invisible to the naked eye. Whether you are conducting routine checks or detailed analysis, TLC plates provide a versatile and reliable solution.
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Millipore concentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied;…
-
Cellulose plates (TLC and HPTLC)
MilliporeSigmaFor analysis of polar substances The organic sorbent cellulose is particularly suitable for the separation of hydrophilic substances by partition chromatography. EMD Millipore cellulose plates include classical TLC grade or HPTLC plates for demanding high-performance separations: TLC…
-
TLC Reagent Sprayers
DWK Life Sciences (Kimble)Provides a uniform spray mist of visualization reagents for both thin layer and paper chromatography Borosilicate glass Handles all standard TLC spray reagents and most corrosive liquids Creates consistent spray patterns that are free of damaging droplets The connection between the sprayer…
-
TLC Silica Gel 60 RP-18 F254s
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
RP-18 W/UV254 Octadecyl-Modified HPTLC Silica Layers
MACHEREY-NAGELFeatures Base material: silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å specific pore volume 0.75 mL/g particle size 2–10 μm for preparative plates (1 mm thickness of layer) standard silica 60 particle size 5–17 µm pH stability…
-
For use as reservoir tray with HTS Transwell Permeable SupportsTC-Treated for cell attachmentSame footprint as standard 24 well plate but with single rectangular wellSterilized by gamma radiation.
-
TLC SILICA GEL 60 W F254S 25 GLASS PLATES 20 X 20 CM
MilliporeSigmaEMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
TLC Aluminium oxide 60 F254, basic
MilliporeSigmaAluminiumoxide plates are used to analyze basic and neutral compounds at different pH levels. Depending on the pH range in question, professionals can choose between two kinds of aluminum oxide plates. Under aqueous conditions, basic aluminum oxide plates are best for separating basic compounds,…
-
Chromatography TLC Sprayers
SP Wilmad-LabGlassWhen using thin layer or paper chromatography (TLC), these borosilicate glass atomizers are used for spraying chromogenic reagents. Complete unit consists of spray head, flask, and LG-1004 clamp. The air inlet tube has an opening to release pressure and stop spraying. All joints are Standard Taper 24/40.
-
Silica Gel G Uniplates
Miles Scientific (Analtech)Silica Gel G & GF UNIPLATES are the most widely used silica gel TLC plates. No organic substances are added to these products, thus making them compatible with sulfuric acid charring visualization.These plates are commonly scraped from the glass backing to isolate separated components for other…
-
-
Nano-DURASIL Unmodified HPTLC Silica Layers
MACHEREY-NAGELFeatures Nano silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 2–10 µm Indicator: manganese activated zinc silicate with green fluorescence for short-wave UV (254 nm) Hard, water-resistant and wettable…
-
Sigma-Aldrich® TLC Plates silica gel matrix
MilliporeSigmamaterial polyester support, silica gel matrix feature binder Polymeric, fluorescent indicator L × W 20 cm × 20 cm layer thickness 200 μm particle size…
-
Silica Gel HLF UNIPLATES
Miles Scientific (Analtech)These are the most rugged silica gel plates available. They not only ease handling and sample application, but also permit the use of up to 80% water in the developing solvent without loss of adherence of the adsorbent layer to the glass plate. Organic binder plates are recommended for all TLC…
-
-
TLC Developing Tank
DWK Life Sciences (Kimble)Constructed of sturdy molded glass bricks Withstands regular use for many years The tank’s clear sides allow for visual inspection of TLC plates up to 20 x 20 cm size. The top of the tank is ground flat to match the lids and the edges are beveled to remove any sharp edges. The bottoms are…
-
10 cm Developing Tank
General Glass BlowingFlat ground top is beveled on the inner and outer rim Ground flat bottom for stability Holds two 10 x 10 cm plates or four 5 x 10 cm plates Thin-Line units allow for faster and more uniform solvent saturated atmosphere and therefore require less solvent. Inside dimensions: 12 x 6.4…
-
PLC SILICA GEL 60, 0.5 MM 20 GLASS PLATES 20 X 20 CM
MilliporeSigmaPLC plates allow users to separate samples that vary greatly in size – from grams down to milligrams. Available with or without a fluorescence indicator, PLC plates has 0.5 mm thickness. They also use the same proven EMD Millipore silica-binder technology as in analytical TLC plates. To…
-
Features Silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å specific pore volume 0.75 mL/g, particle size 5–17 µm available as glass plates with or without fluorescent indicator also available as ALUGRAM® Xtra aluminium sheets Excellent…
-
Silica Gel F TLC Plates
Miles Scientific (Analtech)Analtech’s flexible backed TLC plates offer the same exacting specifications as with the classic glass backed plates assuring batch-to-batch uniformity. Quality is controlled at each step in the manufacturing process — from incoming raw materials to outgoing packaging. Lighter…
-
Glass-Backed Analytical TLC Plates
Miles Scientific (Analtech)This TLC plate can be developed using purely organic, organic/aqueous, and purely aqueous mobile phases. Due to this these plates have been used in numerous applications in normal phase chromatography as well as reversed phase chromatography. Common applications include the analysis of active plant…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
HPTLC Silica Gel 60
MilliporeSigmaThese plates deliver fast and quantitative analysis of complex samples for manual or automated use. EMD Millipore’s HPTLC silica plates work three times faster than conventional TLC plates – and they’re more sensitive. The particle sizes range in HPTLC is between 4-8µm, which creates a smoother…
-
Baker-flex® Coated TLC Cellulose Sheets
Avantor - J.T.Baker®Ready-to-use plastic sheets, 50 x 200 mm or 200 x 200 mm, with absorbent coating, which is abrasion-resistant and highly uniform; are easily cut to desired size and allow sample fraction to be cut rather than scraped The silica gel and aluminum oxide sheets have coating approximately 200 microns…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
Rectangular Developing Tank
General Glass BlowingBeveled inside and outside to remove any sharp edges Raised ridge midway on the inside ends and bottom for developing two 20 x 20 cm plates or the equivalent Inside dimensions: 27 x 7 x 26 cm Supplied with flat glass lid, 30 x 10 x 3 cm Molded glass block of clear glass with…
-
HPTLC Silica Gel 60 Multiformat Pre-scored to 5 x 5 cm
MilliporeSigmaHPTLC plates deliver fast and quantitative analysis of complex samples for manual or automated use. EMD Millipore’s HPTLC silica plates work three times faster than conventional TLC plates – and they’re more sensitive. The particle sizes range in HPTLC is between 4-8µm, which creates a smoother…
-
TLC SILICA GEL 60 50 ALUMINIUM SHEETS 5 X 10 CM
MilliporeSigmaEMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
HPTLC SILICA GEL 60 RP-18 F254S 25 GLASS PLATES 10 X 10 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Milliporeare well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
Fibrous cellulose impregnated with polyethyleneimine available as POLYGRAM® polyester sheets with or without fluorescent indicator Recommended application: analysis of nucleic acids, and of mutagenic substances with the 32P postlabelling procedure
![Site Search powered by SLI Systems](http://assets.resultspage.com/logos/sli_logo_2014.png)