ICP-MS Nebulizers
These nebulizers convert liquid samples into aerosols, which are then transported into the plasma torch for analysis. The precision of ICP-MS Nebulizers, particularly those from the nebulizer ICP range, allows for detecting trace elements and isotopes at extremely low concentrations, making them invaluable in environmental monitoring and geochemistry. Their design ensures minimal sample loss and maximizes analytical sensitivity, offering reliable and consistent performance.
By providing a seamless interface between liquid samples and high-temperature plasma, these nebulizers support the advanced analytical capabilities of ICP-MS systems, contributing to the generation of accurate and reproducible results.
-
PFA-ST nebulizer for prepFAST
PerkinElmerPFA-ST self-aspirating nebulizer for prepFAST, with external 1/4-28 threaded connector.
-
-
Concentric Quartz Nebulizer, MEINHARD Type A3
PerkinElmerThe MEINHARD concentric glass nebulizer reflects exacting standards in design and manufacturing. Its advantages include simplicity of design and operation, reproducible and self-aligning aerosol, and close fabrication control.
-
Low-Flow GemCone for Optima 3X00 Nebulizer
PerkinElmerCan be used with either the glass Cyclonic spray chamber or the Ryton ® MEINHARD ® end cap. RequiresMEINHARD ® End Cap II, P/N N0680504, when used with the Ryton ® double-pass, Scott-type spray chamber(glass or Ryton).
-
This kit includes: MicroMist ™ Nebulizer, Qty. 1 (N0775342) Quartz Cyclonic Spray Chamber, Qty. 1 (WE025221) 2 mm I.D. Quartz Bore Injector, Qty. 1 (WE023948) Tygon Tubing 3.175 mm I.D., Qty. 1 (02506516) 3.175 mm Tubing Insert, Qty. 1 (09903094) Front Ferrule for 6.35 mm Tube Fitting, Qty.…
-
ST3 MicroFlow PFA nebulizer
PerkinElmerThe ST3 MicroFlow PFA nebulizer has an exchangeable external sample uptake capillary. The sample uptake rate is controlled by the diameter of the external capillary or probe.
-
Gem tip Cross-Flow II Tip Kits for Optima 8x00
PerkinElmerThe PerkinElmer GemTip Cross-Flow II Tip Kit is for use with the Optima 8x00 ICP-OES. Excellent general purpose nebulizer for the analysis of strong mineral acids (including HF) and samples with less than 5% dissolved solids. The Tip Kit includes a clear sapphire sample tip and a red ruby argon…
-
The PEEK Ari Mist ® nebulizer provides very low sample flow and is for samples that are particlate free. Operates on stand pressures of 40 - 50 psi. Fits regular spray chambers as a direct replacement for glass concentric nebulizers. Its features an enhanced parallel path design.
-
Nebulizer liquid fitting with ETFE capillary tubing - 4 length by 0. 020 ID x 0. 062 OD flanged onto female CTFE fitting Includes one male barb CTFE fitting.
-
2 mm gas line with UpChurch fingertight fittings for Mira Mist and Ari Mist nebulizers.
-
MicroFlow nebulizers are resistant to clogging, reliably self-aspirated or pumped to produce a fine aerosol for high transport efficiency and high sensitivity. The PFA-ST3 Nebulizer is designated for superior clog resistance and higher sensitivity compared to the standard PFA nebulizer. • All PFA…
-
ICP-OES Nebulizers
Agilent TechnologiesAgilent offers a wide range of concentric and microconcentric glass nebulizers to facilitate sample introduction for a variety of ICP-OES measurements. Nebulizer styles can accommodate samples with up to 20% total dissolved solids (TDS) and slurry samples containing more than 20% total dissolved…
-
The SeaSpray Concentric Nebulizer is ideal for samples with high dissolved solids and offers outstanding nebulization effciency for trace level analysis. It offers freedom from clogging while nebulizing solutions near the limit of solubility of most mineral salts, and conferring signifcant…
-
Cross-Flow II Replacement GemTip for ICP-MS
PerkinElmerIncludes a color coded set of ruby and sapphire GemTips optimized for use with ICP-MS. Orifice size: argon, (0.23mm, 0.009in) ruby red; sample, (0.34mm, 0.013in) clear. For use with the Cross-Flow II Nebulizer only.
-
Capillary Tubing 18 0.043 x 0.017 for Mira Mist
PerkinElmer0. 5 meters of . 044 OD X . 018 ID. Clear Polyethylene Tubing with attached BRC 3 fitting for sample lines.
-
200 uL/min self-asp capillary
PerkinElmer200 µL/min self-aspirating sample capillary for ST nebulizer. 0.30 mm i.d., yellow marker
-
Quick Release 2000/4000/5000-Mira Mist
PerkinElmerQuick Release for PE Optima 2000, 4000, 5000 series.
-
The MEINHARD concentric glass nebulizers reflect exacting standards in design and manufacturing. They provide excellent sensitivity and precision for aqueous solutions and samples with few dissolved solids (less than 1%). MEINHARD nebulizers for Optima instruments include Standard Nebulizer…
-
Type A0.5 Quartz Nebulizer for NexION
PerkinElmerThe MEINHARD® Concentric Nebulizer reflects exacting standards in design and manufacturing. Its advantages include simplicity of design and operation, reproducible and self-aligning aerosol, and close fabrication control. They provide excellent sensitivity and precision for aqueous solutions and…
-
PFA-200 Microflow Nebulizer 20 uL/min
PerkinElmerPFA-200 Microflow Nebulizer, 200 µL/min, with integrated autosampler probe [Ultem support] for ESI SC Autosampler. HF Resistant. Capillary length 150cm. Probe length 175 mm.
-
Fused Silica Obstruction Removal Kit for ST type Nebulizers. Used to clear blockage from ST type nebulizers. Inc Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final…
-
Concentric Glass Nebulizer, MEINHARD Type C
PerkinElmerThe MEINHARD® concentric glass nebulizer reflects exacting standards in design and manufacturing. Its advantages include simplicity of design and operation, reproducible and self-aligning aerosol, and close fabrication control. For use with high dissolved solids solutions.
-
Eluo Nebulizer Cleaner
PerkinElmerEluo Nebulizer Cleaner Particle build-up in a nebulizer capillary and tip causes sample flow to be constricted, thereby reducing nebulizer efficiency andperformance. Previously there was no simple way to effectively clean and unblock nebulizers. Now, blocked nebulizers can be safelyand easily…
-
F2 Standard Integrated Capillary
PerkinElmerF2 Standard Integrated Capillary (standard fitting with + nebulizers). F2 Standard integrated capillary for self-aspiration or pumping. Includes 0. 5 mm i.d. (orange marker) 70 cm long capillary.
-
Type C0.5 Glass Nebulizer for NexION
PerkinElmerThe MEINHARD® Concentric Nebulizer reflects exacting standards in design and manufacturing. Its advantages include simplicity of design and operation, reproducible and self-aligning aerosol, and close fabrication control. They provide excellent sensitivity and precision for aqueous solutions and…
-
-
EzyLok Kit for Glass Concentric Nebulizers
PerkinElmerIncludes: EzyLok Connector for 4mm Tubing EzyLok 6mm Hose Adaptor Nebulizer Hose Clip
-
The SeaSpray ™ concentric nebulizer is ideal for samples with high dissolved solids and offers outstanding nebulization ef ciency for trace level analyses. It offers freedom from clogging while nebulizing solutions to the limit of solubility of most mineral salts and conferring significant…
-
Nebulizers And Nebulizer Supplies
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
SeaSpray U-Series Nebulizer 1mL/min
PerkinElmerMaterial: Borosilicate glass High physical reproducibility ~ 1%, TDS tolerance, typically up to 20%, High tolerance to particulates, typically up to 75um, Low RSD's due to highly accurate construction
-
Replacement connector and sample tubing for glass concentric nebulizers with EzyFit sample inlet.
-
The Cross-Flow II Nebulizer is made completely from chemically inert non-metallic materials. With new GemTips optimized for ICP-MS(0. 009in and 0. 013in orifices), the new ICP-MS Cross-Flow II Nebulizer is specially manufactured and cleaned for ultra-trace analysis. Providing high sensitivity and…