Air Samplers

Compare Tool

Select up to 3 products

HomeAll Products

Air Air Samplers

1 - 32 of 69
Sort
View
Show
  • With standard U shape gauge made of heavy barometer tubing and mounted on a wooden panel for vertical suspension. The scale is adjustable and accurately calibrated. Supplied with scale and tubes, but without mercury.

  • quick-ship

    Dräger

    DrägerTubes® are glass vials filled with a chemical reagent that reacts to a specific chemical or family of chemicals. A calibrated 100mL sample of air is drawn through the tube with the Dräger accuro® bellows pump. If the targeted chemical(s) is present the reagent in the…

  • Ace Glass

    Impingers used for sampling small air volumes at low velocities. Bottle with 24/40 stopper joint is available in 25 or 30ml sizes. The stopper is available with an open nozzle or one calibrated to deliver 0.09 to 0.11 CFM at 30.5cm (12in) vacuum. The stopper inlet is available as an open tube end,…

  • Collection bottle, usually connected to the bottom arm of the 7495 tee with reduced ends, to collect heavy particulates before they enter the manifold train.

  • Ace Glass

    Glass Manifold with #15 Ace-Thred at either end To allow switching 5853 vacuum connection to left or right side. Supplied with three or five, 4mm straight bore PTFE stopcock sampling ports. (Additional ports can be ordered.) Overall length of glass manifold is 230mm. Complete item consists of 8763…

  • Ace Glass

    Bubbler with either fritted tip or plain orifice stopper. Bottle has 24/40 joint and 10 cm tube below bulge. Stopper has 12/5 outer joint on inlet arm and 12/5 inner on outlet arm. Fritted tip is porosity C (25-50m). Orifice tip is 1.5mm capillary with end tapered. Approximate capacity, with…

  • Borosilicate glass vacuum/NO-AIR trap. Simliar to 8755 traps but with No. 15 O-Ring side connecting joints. Ideal for vacuum cart and other vacuum or NO-AIR applications. Comes complete with stainless steel ball-joint clamp and Viton O-Ring.

  • Carbon Adsorbers and Filters Change Indicators for Acids, Ammonia, Ammonia & Hydrogen Sulfide, Aromatic Diisocyanates, Basic Vapors, Halogens, Hydrazine, Formaldehyde, Hydrogen Sulfide and Mercury. The breakthrough (saturation) indicators are colorimetric indicators that indicate the…

  • Schlenk style reaction tube for vacuum and No-Air applications. Available in many capacities, joint sizes and side arm configurations including a glass stopcock, 0-3 inlet valve or a 0-4 Hi-Vac valve.

  • Flexible Non contaminating On/off valve closure Use for gas or liquid sample containment Heat-sealed seams for leak-proof operation Reusable bags made of 2 mil PVDF fluoropolymer film, Chemware® Gas Bags offer an economical alternative for analysis of non-corrosive gases.…

  • Schlenk style reaction tube for vacuum and No-Air applications. Available in many capacities, joint sizes and side arm configurations including a glass stopcock, 0-3 inlet valve or a 0-4 Hi-Vac valve.

  • Filter support assembly for collecting dust particles in a stack sampling system. Available in either 51mm (2"), 76mm (3") or 102mm (4") (illustrated) size. Consists of: PART A, with 28/15 outer joint bent perpendicular to flow path; PART B, with seat for fritted disc and 28/15 inner…

  • Imhoff sedimentation cone for the determination of settleable matter in water. Either blunt tip or Ace-Thred tip for environmental applications. Graduated from 0-2ml in 0.1ml divisions, 2-10ml in 0.5ml divisions, 10-40ml in 1ml divisions, 40-100ml in 2ml divisions.

  • Double tube vacuum manifold with 35/20 ball at one end and two 24/40 outer standard taper joints at the other end. Available in either 3 or 4 port configuration with 4mm double oblique stopcocks. Can be ordered with 14/20, 24/40 inner joints or #15 o-ring joints on each port. Distance between ports…

  • Aromatic Diisocyanates, TDI & MDI (Polyurethane Chemicals), Hydrazine (MIL-P-87930, H-70), Hydrogen Sulfide and Mercury. Chemteq Area Monitors are direct-read colorimetric indicators that indicate the presence of trace toxic chemicals in air. They are reliable and cost effect means for…

  • The SAS Super 100 & 180 microbial air samplers are the top choices of the world's leading pharmaceutical and food companies, as well as numerous governments around the world for detection of microbial contamination and air quality testing. Featuring a powerful, high volume air flow of…

  • Permanent split capacitor, steel housed blower used to pull air through our Air Sampling manifolds. Blower produces 50 cfm @ 0.0 meters of water static pressure which assures a minimum pressure drop across each port in the manifold train. Free air rpm is 3030. Available in both 115 & 230v…

  • Flexible Non contaminating Septum closure Use for gas or liquid sample containment Heat-sealed seams for leak-proof operation Reusable bags made of 2 mil PVDF fluoropolymer film, Chemware® Gas Bags offer an economical alternative for analysis of non-corrosive gases. Durable, heat-sealed seams…

  • Filters Breakthrough Indicators Inline for Acids, Ammonia, Ammonia & Hydrogen Sulfide, Basic Vapors, Formaldehyde, Humidity, Hydrazine, Hydrogen Sulfide and Mercury. The BTI Inline is colorimetric indicator that indicate the saturation and exhaustion of carbon adsorbers and filters.The BTI…

  • Sweep elbow, available with one end threaded, the other end reduced for use with 7506 bushing or both ends threaded for use with either 7506 bushing or 5841 coupling.

  • Thomas No. 1165A11 14/20 vacuum adapter, 30mm stem below the joint. Thomas No. 1165A12 14/20 vacuum adapter, 175mm stem below the joint. Thomas No. 1165A13 19/22 vacuum adapter, 30mm stem below the joint.

  • Real-time filter breakthrough indicators. You don't have to change your filter in 3 months, 6 months or 9 months, change your filter only when exhausted and saturated using real-time breakthrough indicators. Get the most use of your filters and protect yourself from exposure to toxic chemicals.…

  • Graduated Schlenk storage tube with 14/20 or 24/25 outer top joints, 14/35 or 24/40 inner joint side arms, stopcock inlet or hose barbed inlet valve. Reaction accessories include 7759 series filter tubes, 7807 series finger condenser, 9543 series stoppers and 13657-33 stirring magnet..

  • A high velocity impinger (Ref. AGI-4) which passes 12.3 to 12.6L/min. (corrected to engineering standard gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.05in capillary…

  • Vacuum, NO-AIR adapter for vacuum cart, vacuum manifolds and Schlenk lines. Has No. 15 O-Ring joint side port with a Hi-Vac valve for precise flow control and an ACE-THRED bottom outlet.

  • Sartorius

    The MD8 series of air samplers are monitoring devices combined with novel filtration systems for the exceptional recovery of airborne microorganisms. MD8 AirScan: (Integrated) Quantitative detection in sterile areas such as clean rooms/RABS, isolators, or blow-fill-seal machines. …

  • Automatic, adjustable pressure release valve for safer operation of pilot plant or other assemblies where the pressure is of great concern. The tension on the stainless steel spring determines the amount of pressure needed to force the lower piece open. With the spring supplied, the range is 15-50…

  • Used for sampling air volumes at low jet velocity. Bottle joint is 24/40. Stopper uses #7 Ace-Safe removable hose connections for easy connect/disconnect. Impinger nozzle calibrated to deliver 0.09 to 0.11 CFM at 30.5cm (12") H2O vacuum. Bubbler nozzle has sintered glass filter, porosity A…

  • quick-ship

    Environmental Sampling Supply

    The ESS Air Sampling Bag incorporates a two opening system for sampling and extraction. The side port/stem (3/16" OD) allows filling with a pneumatic pump and tubing, and for rapid emptying of the bag. The top of the valve is

  • Micro Essential

    Hydrion Ammonia Meter Test Paper is designed and calibrated to measure the amount of ammonia in air in parts per million wherever there may be actual or potential ammonia pollution. The color chart has matches at 0-5-10-20-50-100ppm. The Hydrion Ammonia Test Kit is especially useful where…

  • Accessories for MD8 air sampling devices

  • Ace Glass

    Identical to 7531-10 with the exception that the nozzle is replaced by a sintered glass filter, porosity A (145-175 microns). Used in determination of Acrolein: 4-Hexylresorcinol Method #1. Bottle has encircling graduations from 0 to 25mL or 0 to 30mL in 5mL divisions. Inlet/ outlet are 7mm O.D.…

Compare Tool

Select up to 3 products